Skip to main content
Schneider Electric LC1E65004V7IN — Contactors

Schneider LC1E65004V7IN Easy TeSys Contactor, 85A AC-1, 4P

MPNLC1E65004V7IN
Obsolete

Schneider Electric Easy TeSys Control, LC1E65004V7IN, 4P(4NO) contactor, AC-1 85A at ≤415V, 400V coil.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LC1E65004V7IN — Identification
ParameterValue
Product / component typeContactor
Series / rangeEasy TeSys
ApplicationResistive load
LC1E65004V7IN — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: 10 MOhm for control circuit
Utilisation categoryAC-1
LC1E65004V7IN — Contacts & Poles
ParameterValue
Pole configuration4P
LC1E65004V7IN — Environmental
ParameterValue
IP degree of protectionIP2X conforming to IEC 60529
Operating altitude3000 m
Mechanical robustnessVibrations contactor open (1.5 Gn, 5...300 Hz) Vibrations contactor closed (3 Gn, 5...300 Hz) Shocks contactor open (6 Gn for 11 ms) Shocks contactor closed (7 Gn for 11 ms)
Protective treatment / pollution degreeTH (pollution degree 3) conforming to IEC 60068
Fire resistance850 °C conforming to IEC 60695-2-1
LC1E65004V7IN — Approvals
ParameterValue
StandardsEN/IEC 60947-1 EN/IEC 60947-4-1 EN/IEC 60947-5-1 GB/T 14048.1 GB/T 14048.4 GB/T 14048.5
LC1E65004V7IN — Mechanical
ParameterValue
Width85 mm
Height127 mm
Depth125 mm

Product details

The Schneider Electric LC1E65004V7IN is a 4-pole (4NO) contactor from the Easy TeSys Control range, rated for AC-1 utilisation category at 85 A on a power circuit up to 415 V. AC-1 covers resistive loads — heaters, lighting banks, or transformer primaries — where the switching current and the load current are essentially the same, so the contactor doesn't need the derating that motor (AC-3) duty would demand. The 400 V coil suits standard three-phase control voltages across most industrial panels. The operating temperature range is -5 to 55 °C, with storage from -60 to 80 °C, and it's rated for altitudes up to 3000 m without derating.

Mechanical and environmental robustness

Rated for vibration resistance at 1.5 Gn (contacts open) and 3 Gn (contacts closed) over 5–300 Hz, and shock resistance at 6 Gn for 11 ms (open) and 7 Gn for 11 ms (closed).

Frequently asked questions

What is the AC-1 current rating and what does it mean?

85 A in AC-1 utilisation category at ≤415 V. AC-1 covers resistive loads — heaters, lighting, transformer primaries — where the switching current equals the load current, so no derating for motor inrush is needed.

What standards does this contactor comply with?

EN/IEC 60947-1, EN/IEC 60947-4-1, EN/IEC 60947-5-1, and the Chinese GB/T 14048.1, GB/T 14048.4, GB/T 14048.5. Fire resistance to 850 °C per IEC 60695-2-1.

How is the LC1E65004V7IN mounted?

On a DIN rail or a mounting plate. The enclosure provides IP2X finger protection.

MPN
LC1E65004V7IN