Skip to main content
Schneider Electric LC1E65008M5WBIN — Contactors

LC1E65008M5WBIN Easy TeSys Contactor, 85 A AC-1, 220 V AC Co

MPNLC1E65008M5WBIN
Active

Schneider Electric Easy TeSys Control LC1E65008M5WBIN, 4-pole contactor, 85 A rated operational current (AC-1 at ≤415 V), 220 V AC 50 Hz coil, screw clamp terminals, DIN rail or plate mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

LC1E65008M5WBIN — Identification
ParameterValue
Product / component typeContactor
Series / rangeEasy TeSys
ApplicationResistive load
LC1E65008M5WBIN — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: <= 690 V AC 50/60 Hz
Utilisation categoryAC-1
LC1E65008M5WBIN — Contacts & Poles
ParameterValue
Pole configuration4P
LC1E65008M5WBIN — Environmental
ParameterValue
IP degree of protectionIP20 conforming to IEC 60529
Operating altitude3000 m
Mechanical robustnessVibrations contactor open (1.5 Gn, 5...300 Hz) Vibrations contactor closed (3 Gn, 5...300 Hz) Shocks contactor open (6 Gn for 11 ms) Shocks contactor closed (7 Gn for 11 ms)
Protective treatment / pollution degreeTH conforming to IEC 60068
Fire resistance850 °C conforming to IEC 60695-2-1
LC1E65008M5WBIN — Approvals
ParameterValue
StandardsEN/IEC 60947-1 EN/IEC 60947-4-1 EN/IEC 60947-5-1 GB/T 14048.1 GB/T 14048.4 GB/T 14048.5
LC1E65008M5WBIN — Mechanical
ParameterValue
Width85 mm
Height127 mm
Depth125 mm

Product details

Spec and fit for the BOM line

The LC1E65008M5WBIN is a 4-pole contactor from the Schneider Electric Easy TeSys Control range, rated for 85 A in AC-1 utilisation category at ≤415 V AC. That 85 A figure governs resistive loads — heaters, ovens, lighting banks — not motor starting. The 220 V AC 50 Hz coil is a wide-range control circuit type, so it pulls in reliably between 0.7 and 1.25 Uc and drops out between 0.3 and 0.6 Uc across -5 to 55 °C. Pole configuration is 2 NO + 2 NC with no auxiliary contacts built in — if your circuit needs aux switching, you add a separate block.

Dimensions are 85 mm wide, 127 mm high, 125 mm deep — that depth matters when you are laying out a shallow enclosure. Power circuit terminals accept 2.5 to 25 mm² flexible with cable end (or solid up to 25 mm²); control circuit terminals take 1 to 4 mm². Tighten the power terminals to 5 N.m, control terminals to 1.2 N.m. No special torque driver needed, but a calibrated screwdriver keeps connection resistance repeatable. Heat dissipation runs 6 to 10 W through the control circuit, plus 6.4 W per pole in AC-1 duty. Average impedance per pole is 1 mOhm at 85 A 50 Hz.

Durability and switching performance

Mechanical life is rated at 5 million cycles; electrical endurance at 350,000 cycles under AC-1 conditions. Maximum operating rate is 1200 cycles per hour at 60 °C. Closing time is 20 to 26 ms, opening 8 to 12 ms — fast enough for most on/off resistive switching, not intended for high-speed chopping. Rated making capacity is 650 A at 440 V AC; breaking capacity is 520 A at 440 V. The associated fuse recommendation is 125 A gG at ≤690 V, coordination type 1, so the fuse clears before the contactor welds on a bolted fault. Vibration resistance is 1.5 Gn (open) and 3 Gn (closed) over 5 to 300 Hz; shock resistance is 6 Gn (open) and 7 Gn (closed) for 11 ms. That is adequate for most industrial panel environments but not for direct mounting on a reciprocating compressor or engine block.

Frequently asked questions

What is the depth of the LC1E65008M5WBIN?

The depth is 125 mm. Combined with the 85 mm width and 127 mm height, it fits standard DIN-rail spacing but requires 125 mm of enclosure depth clearance.

MPN
LC1E65008M5WBIN