Schneider Electric LC1E65F6 — Contactors

Schneider LC1E65F6 Easy TeSys Contactor, 65A AC-3, 110V AC C

MPNLC1E65F6
Obsolete

Schneider Electric Easy TeSys Control, LC1E series, 3-pole contactor, 65 A AC-3/AC-3e at ≤440 V, 110 V AC 50/60 Hz coil, IP2X.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LC1E65F6 — Identification
ParameterValue
Product / component typeContactor
Series / rangeEasy TeSys
ApplicationMotor control Resistive load
LC1E65F6 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: 10 MOhm for control circuit
Utilisation categoryAC-3 AC-3e AC-1
LC1E65F6 — Contacts & Poles
ParameterValue
Pole configuration3P
LC1E65F6 — Environmental
ParameterValue
IP degree of protectionIP2X conforming to IEC 60529
Operating altitude3000 m without derating
Mechanical robustnessVibrations contactor open (1.5 Gn, 5...300 Hz) Vibrations contactor closed (3 Gn, 5...300 Hz) Shocks contactor open (6 Gn for 11 ms) Shocks contactor closed (7 Gn for 11 ms)
Protective treatment / pollution degreeTH (pollution degree 3) conforming to IEC 60068-2-30 test Db
Fire resistance850 °C conforming to IEC 60695-2-1
LC1E65F6 — Approvals
ParameterValue
StandardsEN/IEC 60947-1 EN/IEC 60947-4-1 EN/IEC 60947-5-1 GB/T 14048.1 GB/T 14048.4 GB/T 14048.5 EN/IEC 60335-1:Clause 30.2 EN/IEC 60335-2-40:Annex JJ
LC1E65F6 — Mechanical
ParameterValue
Width75 mm
Height127 mm
Depth114 mm

Product details

It carries a 65 A rating in AC-3 and AC-3e utilisation categories at ≤440 V, meaning it handles the high inrush of squirrel-cage motors during start-up and the lower running current — the AC-3 rating is the one that governs real motor duty, not the higher AC-1 resistive figure. The 110 V AC coil at 60 Hz pulls in the main contacts; the 1.5 ms non-overlap time between NC and NO contacts ensures break-before-make in reversing or interlocking circuits.

IP2X means it's protected against fingers but not moisture; keep it inside a sealed enclosure if there's washdown or condensation.

These standards confirm it's suitable for industrial control panels and motor starter assemblies in most jurisdictions.

Frequently asked questions

What are the key ratings of the LC1E65F6?

It is a 3-pole contactor rated 65 A in AC-3/AC-3e duty at ≤440 V, with a 110 V AC 50/60 Hz coil. It also carries AC-1 resistive load ratings. The non-overlap time between NC and NO contacts is 1.5 ms on both energisation and de-energisation.

What standards does the LC1E65F6 comply with?

It complies with EN/IEC 60947-1, -4-1, and -5-1, plus the Chinese GB/T 14048 series. It also meets glow-wire testing at 850 °C per IEC 60695-2-1 and TH protective treatment for damp heat environments.

How do I source the LC1E65F6?

Since it is obsolete, we source it through surplus and independent distribution channels. Submit an RFQ for a quote; availability depends on what inventory remains in the network.