Specifications

LC1E80004Q7IN — Identification
ParameterValue
Product / component typeContactor
Series / rangeEasy TeSys
ApplicationResistive load
LC1E80004Q7IN — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: 10 MOhm for control circuit
Utilisation categoryAC-1
LC1E80004Q7IN — Contacts & Poles
ParameterValue
Pole configuration4P
LC1E80004Q7IN — Environmental
ParameterValue
IP degree of protectionIP2X conforming to IEC 60529
Operating altitude3000 m
Mechanical robustnessVibrations contactor open (1.5 Gn, 5...300 Hz) Vibrations contactor closed (3 Gn, 5...300 Hz) Shocks contactor open (6 Gn for 11 ms) Shocks contactor closed (7 Gn for 11 ms)
Protective treatment / pollution degreeTH (pollution degree 3) conforming to IEC 60068
Fire resistance850 °C conforming to IEC 60695-2-1
LC1E80004Q7IN — Approvals
ParameterValue
StandardsEN/IEC 60947-1 EN/IEC 60947-4-1 EN/IEC 60947-5-1 GB/T 14048.1 GB/T 14048.4 GB/T 14048.5
LC1E80004Q7IN — Mechanical
ParameterValue
Width95 mm
Height127 mm
Depth120 mm

Product details

The Schneider Electric LC1E80004Q7IN is a 4-pole (4NO) power contactor from the Easy TeSys Control range, rated for AC-1 resistive loads at 110 A up to 415 V. It's built for switching resistive heater banks, lighting banks, or other non-inductive loads where inrush is minimal — the AC-1 utilisation category tells you this isn't the part for motor starting (that's AC-3).

Lifecycle reality — this part is obsolete

The LC1E80004Q7IN is officially obsolete per the manufacturer. That means no further production runs — no factory orders, no standard lead time.

The AC-1 rating of 110 A at ≤415 V is the continuous resistive current the main poles can carry and break. The 4P (4NO) configuration gives four normally-open power poles. Mechanical robustness is specified for vibration (1.5 Gn open, 3 Gn closed) and shock (6 Gn open, 7 Gn closed), which is typical for panel-mounted contactors in industrial environments — not a limiting factor for stationary installs. Ambient temperature range of -20 to 70 °C at coil rated voltage, with operation limited to -5 to 55 °C, means it's fine for a ventilated enclosure but watch the derating if it's packed next to a heat source. The 850 °C glow-wire test per IEC 60695-2-1 and pollution degree 3 (TH treatment) mean it's rated for typical industrial panel environments with conductive dust or condensation.

IP2X means finger-safe terminals, but no washdown rating; keep it inside the panel.

Frequently asked questions

What are the key specifications I need to match?

4-pole (4NO) contactor, AC-1 utilisation category, rated 110 A at ≤415 V. DIN rail or plate mount, IP2X. Dimensions: 95 mm wide, 127 mm high, 120 mm deep. Standards: EN/IEC 60947-1, -4-1, -5-1.