Skip to main content
Schneider Electric LC1E80008B7IN — Contactors

Schneider LC1E80008B7IN Easy TeSys Contactor, 4P(4NO), 110A

MPNLC1E80008B7IN
Obsolete

Schneider Electric Easy TeSys Control series, LC1E80008B7IN contactor, 4P(4NO), AC-1 utilisation category, <=415V rated operational voltage, 110A rated current, 24V 50/60Hz coil.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LC1E80008B7IN — Identification
ParameterValue
Product / component typeContactor
Series / rangeEasy TeSys
ApplicationResistive load
LC1E80008B7IN — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: 10 MOhm for control circuit
Utilisation categoryAC-1
LC1E80008B7IN — Contacts & Poles
ParameterValue
Pole configuration4P
LC1E80008B7IN — Environmental
ParameterValue
IP degree of protectionIP2X conforming to IEC 60529
Operating altitude3000 m
Mechanical robustnessVibrations contactor open (1.5 Gn, 5...300 Hz) Vibrations contactor closed (3 Gn, 5...300 Hz) Shocks contactor open (6 Gn for 11 ms) Shocks contactor closed (7 Gn for 11 ms)
Protective treatment / pollution degreeTH (pollution degree 3) conforming to IEC 60068
Fire resistance850 °C conforming to IEC 60695-2-1
LC1E80008B7IN — Approvals
ParameterValue
StandardsEN/IEC 60947-1 EN/IEC 60947-4-1 EN/IEC 60947-5-1 GB/T 14048.1 GB/T 14048.4 GB/T 14048.5
LC1E80008B7IN — Mechanical
ParameterValue
Width95 mm
Height127 mm
Depth120 mm

Product details

The Schneider Electric LC1E80008B7IN is a 4-pole (4 normally-open) contactor from the Easy TeSys Control range, rated for resistive loads in AC-1 utilisation category up to 415 V and 110 A. The 24 V 50/60 Hz coil makes it a direct fit for control transformers or 24 V control supplies common in panel designs.

The AC-1 rating at 110 A is the key number: this contactor is designed for resistive loads (heaters, lighting banks) where inrush is low. It is not rated for motor starting (AC-3) or inductive loads — using it on a motor circuit would exceed its switching capability and risk contact welding. The 4-pole NO configuration gives you four independent switching paths, each rated for the full 110 A in AC-1, so it can switch a three-phase resistive load plus a neutral or separate control circuit. Mechanical robustness is specified: the contactor withstands 1.5 Gn vibration when open and 3 Gn when closed, plus shock ratings of 6 Gn open and 7 Gn closed. That puts it in the range for industrial panels on factory floors with moderate vibration from nearby machinery or conveyors.

That covers the main industrial control gear standards for contactors and motor starters.

Frequently asked questions

What are the key ratings for this contactor?

It is a 4-pole (4NO) contactor rated for AC-1 resistive loads at 110 A, up to 415 V, with a 24 V 50/60 Hz coil. It mounts on plate or DIN rail and has IP2X finger-safe protection.

What standards does this part comply with?

It complies with EN/IEC 60947-1, EN/IEC 60947-4-1, EN/IEC 60947-5-1, and the Chinese GB/T 14048.1, 14048.4, and 14048.5. Fire resistance is 850 °C per IEC 60695-2-1, and protective treatment is TH (pollution degree 3) per IEC 60068.

MPN
LC1E80008B7IN