Schneider Electric LC1E80008N5WBIN — Contactors

Schneider Easy TeSys LC1E80008N5WBIN Contactor, 110 A AC-1,

MPNLC1E80008N5WBIN
Obsolete

Schneider Electric Easy TeSys LC1E80008N5WBIN, 4-pole contactor, 110 A AC-1 at ≤415 V, 415 V AC 50 Hz coil, screw clamp terminals, IP20.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LC1E80008N5WBIN — Identification
ParameterValue
Product / component typeContactor
Series / rangeEasy TeSys
ApplicationResistive load
LC1E80008N5WBIN — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: <= 690 V AC 50/60 Hz
Utilisation categoryAC-1
LC1E80008N5WBIN — Contacts & Poles
ParameterValue
Pole configuration4P
LC1E80008N5WBIN — Environmental
ParameterValue
IP degree of protectionIP20 conforming to IEC 60529
Operating altitude3000 m
Mechanical robustnessVibrations contactor open (1.5 Gn, 5...300 Hz) Vibrations contactor closed (3 Gn, 5...300 Hz) Shocks contactor open (6 Gn for 11 ms) Shocks contactor closed (7 Gn for 11 ms)
Protective treatment / pollution degreeTH conforming to IEC 60068
Fire resistance850 °C conforming to IEC 60695-2-1
LC1E80008N5WBIN — Approvals
ParameterValue
StandardsEN/IEC 60947-1 EN/IEC 60947-4-1 EN/IEC 60947-5-1 GB/T 14048.1 GB/T 14048.4 GB/T 14048.5
LC1E80008N5WBIN — Mechanical
ParameterValue
Width95 mm
Height127 mm
Depth120 mm

Product details

The Schneider Electric Easy TeSys LC1E80008N5WBIN is a 4-pole contactor rated for resistive load switching under utilisation category AC-1. Its rated operational current is 110 A at ≤415 V AC, 40 °C ambient, which means it is sized for heater banks, lighting stages, or other purely resistive circuits where inrush stays under 1.2× steady-state. The coil is 415 V AC at 50 Hz, a wide-range AC control type that holds in from 0.7 to 1.25 Uc and drops out between 0.3 and 0.6 Uc across the -5 to 55 °C band.

The 110 A AC-1 rating governs the continuous current the main poles can carry without exceeding a 9.7 W per-pole dissipation. That dissipation figure, combined with the 6 to 10 W control-circuit heat loss, matters when the contactor is packed into a sealed enclosure — the total thermal load must be vented or the 40 °C ambient derating curve applies. Breaking capacity is 640 A at 440 V, and making capacity is 800 A at 440 V AC, both conforming to IEC 60947-4-1. These are the fault-clearing and closure-surge limits for the power circuit — the contactor can interrupt a bolted fault up to 640 A and close onto a load drawing up to 800 A peak, provided the upstream protection (a 160 A gG fuse at ≤690 V, coordination type 1) clears any higher fault. The 4-pole configuration is 2 NO + 2 NC, with no built-in auxiliary contact block. If you need feedback to a PLC or a seal-in circuit, an add-on block will be required — the base contactor carries only the main poles.

Mounts on either a DIN rail or a plate, per the mounting support spec. The IP20 finger-safe protection means it is suitable for installation inside a locked panel but not in a washdown or outdoor location without an outer enclosure. Power-circuit terminals accept 4 to 50 mm² solid or flexible cable with a ferrule, tightened to 12 N·m. Control-circuit terminals take 1 to 4 mm² solid or flexible (1 to 2.5 mm² with ferrule) at 1.2 N·m.

The TH protective treatment per IEC 60068 indicates the contactor is treated for tropical/humid environments.

Mechanical and electrical endurance

Rated for 350,000 electrical cycles under AC-1 load and 3,000,000 mechanical cycles. The maximum operating rate is 1,200 cycles per hour at 60 °C. Vibration resistance is 1.5 Gn (open) and 3 Gn (closed) across 5 to 300 Hz; shock resistance is 6 Gn open, 7 Gn closed for 11 ms. These figures confirm suitability for machinery with moderate vibration, provided the contactor is not expected to switch under those vibration levels.

Frequently asked questions

What is the rated operational current and utilisation category?

The rated operational current is 110 A at ≤415 V AC under utilisation category AC-1, meaning it is designed for resistive loads such as heaters or lighting.

What is the control circuit voltage?

The control circuit voltage is 415 V AC at 50 Hz, with a wide-range AC control type that operates between 0.7 and 1.25 Uc and drops out between 0.3 and 0.6 Uc.

What standards does this contactor comply with?

It complies with EN/IEC 60947-1, EN/IEC 60947-4-1, EN/IEC 60947-5-1, and the Chinese GB/T 14048.1, GB/T 14048.4, and GB/T 14048.5 standards.