Schneider Electric LC1E80R6 — Contactors

Schneider LC1E80R6 Easy TeSys Contactor, 80A AC-3, 440V 60Hz

MPNLC1E80R6
Obsolete

Schneider Electric Easy TeSys Control LC1E, 3P(3NO) contactor, 80 A AC-3/AC-3e at ≤440 V, 440 V AC 60 Hz coil, DIN rail or plate mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LC1E80R6 — Identification
ParameterValue
Product / component typeContactor
Series / rangeEasy TeSys
ApplicationMotor control Resistive load
LC1E80R6 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: 10 MOhm for control circuit
Utilisation categoryAC-3 AC-3e AC-1
LC1E80R6 — Contacts & Poles
ParameterValue
Pole configuration3P
LC1E80R6 — Environmental
ParameterValue
IP degree of protectionIP2X conforming to IEC 60529
Operating altitude3000 m without derating
Mechanical robustnessVibrations contactor open (1.5 Gn, 5...300 Hz) Vibrations contactor closed (3 Gn, 5...300 Hz) Shocks contactor open (6 Gn for 11 ms) Shocks contactor closed (7 Gn for 11 ms)
Protective treatment / pollution degreeTH (pollution degree 3) conforming to IEC 60068-2-30
Fire resistance850 °C conforming to IEC 60695-2-1
LC1E80R6 — Approvals
ParameterValue
StandardsEN/IEC 60947-1 EN/IEC 60947-4-1 EN/IEC 60947-5-1 GB/T 14048.1 GB/T 14048.4 GB/T 14048.5 EN/IEC 60335-1:Clause 30.2 EN/IEC 60335-2-40:Annex JJ
LC1E80R6 — Mechanical
ParameterValue
Width85 mm
Height127 mm
Depth121 mm

Product details

The Schneider Electric LC1E80R6 is a three-pole contactor from the Easy TeSys Control range, rated 80 A in AC-3 and AC-3e utilisation categories at ≤440 V, with a 440 V AC 60 Hz coil. The contactor is certified to EN/IEC 60947-1, 60947-4-1, and 60947-5-1, plus GB/T equivalents, and passes a 850 °C glow-wire test per IEC 60695-2-1 for fire resistance.

For a replacement, you will need to evaluate a parametric cross-reference based on your specific load and coil voltage — the Easy TeSys Control family has current-production siblings, but pin-compatibility and footprint should be verified against the panel layout.

The 80 A AC-3 rating governs motor switching — that is the current the contactor can make and break across a typical induction motor load. The AC-3e category adds an energy-saving classification for motors with electronic controllers. The AC-1 rating covers resistive loads at a higher continuous current, but the exact AC-1 value is not listed here. The 440 V AC coil means this contactor is designed for a 440 V control circuit at 60 Hz. If your control voltage is different, the coil must be swapped or a different variant selected. Operating altitude is 3000 m without derating, and the permissible ambient temperature range is -5 to 55 °C for operation, with storage from -60 to 80 °C.

Frequently asked questions

What replaces the LC1E80R6?

No official successor order code is provided by the manufacturer. A parametric replacement from the current Easy TeSys Control range would need to match the 80 A AC-3 rating, 3-pole configuration, 440 V AC 60 Hz coil, and DIN-rail footprint — verify pin-compatibility and dimensions before substituting.

What are the key ratings of the LC1E80R6?

It is a 3-pole contactor rated 80 A in AC-3/AC-3e at ≤440 V, with a 440 V AC 60 Hz coil. It also covers AC-1 resistive loads. It mounts on DIN rail or plate, has IP2X protection, and operates from -5 to 55 °C ambient.

MPN