Skip to main content
Schneider Electric LC1E95M6 — Contactors

Schneider Electric LC1E95M6 Easy TeSys Contactor, 95A AC-3,

MPNLC1E95M6
Active

Schneider Electric Easy TeSys Control, LC1E95M6, 3P(3NO) contactor, AC-3 95A at ≤440V, 220V AC coil 60Hz, IP2X.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LC1E95M6 — Identification
ParameterValue
Product / component typeContactor
Series / rangeEasy TeSys
ApplicationMotor control Resistive load
LC1E95M6 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: 10 MOhm for control circuit
Utilisation categoryAC-3 AC-3e AC-1
LC1E95M6 — Contacts & Poles
ParameterValue
Pole configuration3P
LC1E95M6 — Environmental
ParameterValue
IP degree of protectionIP2X conforming to IEC 60529
Operating altitude3000 m without derating
Mechanical robustnessVibrations contactor open (1.5 Gn, 5...300 Hz) Vibrations contactor closed (3 Gn, 5...300 Hz) Shocks contactor open (6 Gn for 11 ms) Shocks contactor closed (7 Gn for 11 ms)
Protective treatment / pollution degreeTH (pollution degree 3) conforming to IEC 60068-2-30 test Db
Fire resistance850 °C conforming to IEC 60695-2-1
LC1E95M6 — Approvals
ParameterValue
StandardsEN/IEC 60947-1 EN/IEC 60947-4-1 EN/IEC 60947-5-1 GB/T 14048.1 GB/T 14048.4 GB/T 14048.5 EN/IEC 60335-1:Clause 30.2 EN/IEC 60335-2-40:Annex JJ
LC1E95M6 — Mechanical
ParameterValue
Width85 mm
Height127 mm
Depth121 mm

Product details

The Schneider Electric LC1E95M6 is a 3-pole contactor from the Easy TeSys Control range, rated for 95 A in AC-3 duty at ≤440 V with a 220 V AC 60 Hz coil. That AC-3 rating means it's sized for starting and stopping squirrel-cage induction motors under load — the 95 A figure is the actual motor current it can switch, not a resistive heating number.

Standards and compliance — what they certify

The LC1E95M6 carries approvals to EN/IEC 60947-1 (general rules), 60947-4-1 (contactors and motor-starters), and 60947-5-1 (control circuit devices), plus the Chinese GB/T equivalents. These are the core standards for industrial switching gear — 60947-4-1 specifically covers the thermal and switching endurance for motor loads. It also meets IEC 60335-1 Clause 30.2 for glow-wire testing on household appliance circuits, and IEC 60695-2-1 for fire resistance at 850 °C.

Depth is 121 mm, which is typical for this frame size; account for that when laying out gland plates and door clearance. IP2X finger protection on the front face means it's safe for open-panel mounting where operators might reach in, but it's not sealed — no IP65, so keep it inside an enclosure for washdown zones.

Environmental limits and mechanical robustness

Operates from -5 °C to 55 °C ambient, stores from -60 °C to 80 °C, and derates above 3000 m altitude. The vibration spec is 1.5 Gn (5-300 Hz) with contacts closed, 3 Gn closed — that's moderate industrial floor vibration, fine for most fixed-mount motor control centers but not for direct engine-mount applications. Shock resistance is 6 Gn open, 7 Gn closed — typical for a contactor in a panel on a factory floor, not for mobile equipment.

Frequently asked questions

What are the key ratings I need to verify for fit?

The critical ratings are the AC-3 current of 95 A at ≤440 V and the coil voltage of 220 V AC 60 Hz. The contactor is 3-pole (3NO) and mounts on DIN rail or plate.

What standards does this contactor comply with?

It complies with EN/IEC 60947-1, 60947-4-1, and 60947-5-1, plus the Chinese GB/T equivalents. It also meets IEC 60335-1 Clause 30.2 for appliance circuits and IEC 60695-2-1 for fire resistance at 850 °C.

What is the closest alternative in the Easy TeSys family?

The closest sibling is the LC1E95M7, which shares the same 95 A AC-3 rating and 3-pole configuration but uses a 220 V AC 50 Hz coil instead of 60 Hz. The LC1E95M6 is the 60 Hz variant; if your control voltage is 50 Hz, the M7 is the direct swap. No pinout or mounting difference — same footprint, same terminal layout.

MPN
LC1E95M6