Skip to main content
Schneider Electric LC1F1154G6L — Contactors

Schneider LC1F1154G6L TeSys F Contactor, 200 A AC-1, 120 VAC

MPNLC1F1154G6L
Obsolete

Schneider Electric TeSys F LC1F1154G6L, 4-pole contactor, 200 A rated operational current (AC-1), 120 V AC 60 Hz coil, plate mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LC1F1154G6L — Identification
ParameterValue
Product / component typeContactor
ApplicationResistive load
LC1F1154G6L — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)<= 460 V DC
Utilisation categoryAC-1
LC1F1154G6L — Contacts & Poles
ParameterValue
Pole configuration4P
LC1F1154G6L — Environmental
ParameterValue
IP degree of protectionIP2X front face with shrouds IEC 60529 IP2X front face with shrouds VDE 0106
Operating altitude9842.52 ft (3000 m) without derating
Mechanical robustnessVibrations contactor open2 Gn, 5...300 Hz Vibrations contactor closed6 Gn, 5...300 Hz Shocks contactor open9 Gn for 11 ms Shocks contactor closed15 Gn for 11 ms
Protective treatment / pollution degreeTH
LC1F1154G6L — Approvals
ParameterValue
StandardsEN 60947-1 IEC 60947-1 IEC 60947-4-1 JIS C8201-4-1 EN 60947-4-1
LC1F1154G6L — Mechanical
ParameterValue
Width7.9 in (200.5 mm)
Height10.4 in (265 mm)
Depth6.7 in (171 mm)

Product details

The Schneider LC1F1154G6L is a 4-pole (4 NO) TeSys F contactor rated for 200 A in AC-1 utilisation category, meaning it is designed for resistive loads — heaters, ovens, lighting banks — not for motor starting (that would be AC-3). The coil pulls 120 V AC at 60 Hz, with an inrush of 660 VA at 60 Hz and a hold-in draw of 55 VA. Closing time runs 23 to 35 ms; opening is faster at 5 to 15 ms. That operating speed matters when you need to sequence multiple contactors in a heating zone — the spread is tight enough to avoid overlap on a resistive bank.

This is a plate-mount contactor (no DIN-rail clip), so plan for a backplate or sub-panel. Dimensions are 7.9 in wide by 10.4 in tall by 6.7 in deep — that is a substantial footprint, roughly the size of a small loaf. Power connections are bolted, accepting two bars 20 x 3 mm or ring terminals up to 95 mm². Torque the power circuit to 88.5 lbf·in (10 N·m) and the control circuit to 10.6 lbf·in (1.2 N·m).

The headline number is 200 A at ≤ 440 V AC in AC-1 duty. That is the resistive load rating — do not use it for motor starting at that current without derating to AC-3. For motor loads, the UL/CSA horsepower ratings are the ones to watch: 30 hp at 200 V AC, 40 hp at 230 V AC, 75 hp at 460 V AC, and 100 hp at 575 V AC. The rated breaking capacity is 920 A per IEC 60947-4-1, and the associated fuse recommendation is 125 A aM or 200 A gG at ≤ 440 V. The contactor is TH-treated for tropical environments (protective treatment against humidity and fungus).

Frequently asked questions

What is the closest alternative to the LC1F1154G6L in the TeSys F family?

The closest active replacement would be a current-production TeSys F contactor with the same 4-pole, 200 A AC-1 rating and 120 VAC coil. The exact order code depends on the current catalogue; contact us with your RFQ and we can cross-reference the official successor.

Where can I buy the LC1F1154G6L?

We source the LC1F1154G6L through independent distribution and surplus channels. It is quoted to order against an RFQ — availability and current pricing are confirmed at quote time.

What are the key specifications of the LC1F1154G6L?

It is a 4-pole (4 NO) contactor rated 200 A in AC-1 (resistive load) at ≤ 440 V AC, with a 120 V AC 60 Hz coil. Dimensions are 7.9 x 10.4 x 6.7 in. It is plate-mount, IP2X front face, and rated for 30-100 hp depending on voltage (UL/CSA).

MPN
LC1F1154G6L