Skip to main content
Schneider Electric LC1F1400GD — Contactors

LC1F1400GD TeSys F Contactor, 1400 A AC-1, 3P, 125 V DC

MPNLC1F1400GD
Obsolete

Schneider Electric TeSys F LC1F1400GD, 3-pole contactor, 1400 A AC-1, 125 V DC coil, plate mount, IEC/UL/CSA.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

LC1F1400GD — Identification
ParameterValue
Product / component typeContactor
Series / rangeTeSys
ApplicationResistive load

Ratings & Performance

LC1F1400GD — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)<= 460 V DC
Utilisation categoryAC-1

Contacts & Poles

LC1F1400GD — Contacts & Poles
ParameterValue
Pole configuration3P

Environmental

LC1F1400GD — Environmental
ParameterValue
Operating altitude3000 m without derating
Protective treatment / pollution degreeTH

Approvals

LC1F1400GD — Approvals
ParameterValue
StandardsIEC 60947-4-1 EN 60947-1 IEC 60947-1 JIS C8201-4-1 EN 60947-4-1 UL 60947-4-1 CSA C22.2 No 60947-4-1

Mechanical

LC1F1400GD — Mechanical
ParameterValue
Width438 mm
Height332 mm
Depth238.6 mm

Product details

The 125 V DC coil pulls in at 0.85–1.1 Uc and drops out between 0.3–0.5 Uc at 55 °C — a standard DC control curve that plays well with PLC relay outputs or dedicated DC supplies in the panel. Plate-mounted, not DIN-rail; plan for the 438 mm width and 332 mm height footprint on the backplate. This is a heavy-current AC-1 machine — think resistive heating banks, large furnace elements, or distribution switching where the load current stays sinusoidal and inrush is low.

Lifecycle reality — EOL phase, sourced to order

If the application can tolerate a parametric substitute, a TeSys F contactor with the same pole count, coil voltage, and AC-1 current class is the starting point — but pinout, mounting hole pattern, and auxiliary wiring must be verified against the panel layout. The 238.6 mm depth and 438 mm width are the mechanical envelope to match.

AC-1 at 1400 A is the headline number, but the short-time withstand (Icw) tells you what this contactor can survive during a fault: 8000 A for 10 seconds, 6000 A for 30 seconds, tapering to 2600 A for 10 minutes — all at 40 °C. That means upstream protection (fuse or breaker) must clear before the contactor's thermal limit is reached. The associated fuse recommendation is 1600 A gG at ≤ 440 V. Heat dissipation is 10 W holding (coil) plus 150 W per pole in AC-1 service — total 460 W dumped into the enclosure at full load. That drives ventilation or cabinet sizing; don't bury this in a sealed box without airflow. Operating time is 50–60 ms closing, 45–60 ms opening — consistent with a large DC-coil contactor. Not a fast-switching device; fine for resistive load on/off, not for high-speed cycling (max 600 cycles/hour at 55 °C).

The LC1F1400GD carries IEC 60947-4-1, EN 60947-1, UL 60947-4-1, and CSA C22.2 No 60947-4-1 approvals — accepted in North American and European panels. Rated insulation voltage is 1000 V per IEC/UL, 1500 V per VDE 0110 group C. Impulse withstand is 8 kV, overvoltage category III. Protective treatment TH indicates tropicalized (humid/condensing environment) capability.

Frequently asked questions

What replaces LC1F1400GD?

No official successor is listed in the lifecycle record. A parametric substitute from the TeSys F family with the same pole count, coil voltage, and AC-1 current class may fit, but mechanical dimensions and wiring must be verified against the existing panel layout.

Where can I buy LC1F1400GD?

Sourced through independent distribution against an RFQ — availability and current pricing are confirmed at quote time.

What compliance documentation does this brand provide for LC1F1400GD?

The contactor is certified to IEC 60947-4-1, EN 60947-1, UL 60947-4-1, and CSA C22.2 No 60947-4-1. Protective treatment is TH (tropicalized).

MPN
LC1F1400GD