Skip to main content
Schneider Electric LC1F1400L7 — Contactors

Schneider TeSys F LC1F1400L7 Contactor, 1400 A AC-1, 3P, 208

MPNLC1F1400L7
Obsolete

Schneider Electric TeSys F series, LC1F1400L7, 3-pole contactor, 1400 A AC-1, 208 VAC 40-400 Hz coil, plate mount.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

LC1F1400L7 — Identification
ParameterValue
Product / component typeContactor
Series / rangeTeSys
ApplicationResistive load

Ratings & Performance

LC1F1400L7 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)<= 460 V DC
Utilisation categoryAC-1

Contacts & Poles

LC1F1400L7 — Contacts & Poles
ParameterValue
Pole configuration3P

Environmental

LC1F1400L7 — Environmental
ParameterValue
Operating altitude3000 m without derating
Protective treatment / pollution degreeTH

Approvals

LC1F1400L7 — Approvals
ParameterValue
StandardsEN 60947-1 EN 60947-4-1 IEC 60947-1 JIS C8201-4-1 IEC 60947-4-1 UL 60947-4-1 CSA C22.2 No 60947-4-1

Mechanical

LC1F1400L7 — Mechanical
ParameterValue
Width438 mm
Height332 mm
Depth238.6 mm

Product details

1400 A AC-1 contactor, 208 VAC coil — TeSys F frame

The Schneider Electric TeSys F LC1F1400L7 is a 3-pole contactor rated for 1400 A in AC-1 utilisation category, meaning it handles resistive loads (heaters, lighting banks, non-inductive furnaces) at that current. The 208 VAC control coil operates across 40-400 Hz, with a pickup range of 0.85-1.1 Uc and dropout between 0.3-0.5 Uc at 55 °C. This is a plate-mount frame — no DIN-rail clip. At 438 mm wide, 332 mm tall, and 238.6 mm deep, it lands in a bolted panel or enclosure backplate, not a standard cabinet rail. Power circuit connections use busbars up to 100 x 5 mm; control wiring terminates on screw clamp terminals accepting 1-4 mm² flexible or solid.

Lifecycle — end-of-life, sourced to order

The LC1F1400L7 is end-of-life (EOL) per manufacturer lifecycle data.

AC-1 duty and breaking capacity

Rated breaking capacity is 2100 A per IEC 60947-4-1, and short-time withstand (Icw) holds 8000 A for 10 seconds, 6000 A for 30 seconds — enough for coordination with upstream 1600 A gG fuses at ≤440 V. Heat dissipation runs 36 W total (150 W per pole in AC-1), so panel ventilation matters at full load. Average impedance is 0.1 mOhm at 1700 A Ith, 50 Hz.

Certified to EN 60947-1, EN 60947-4-1, IEC 60947-1, JIS C8201-4-1, IEC 60947-4-1, UL 60947-4-1, and CSA C22.2 No 60947-4-1. Rated insulation voltage (Ui) is 1000 V per IEC/UL, 1500 V per VDE 0110 Group C. Impulse withstand (Uimp) is 8 kV, overvoltage category III. Protective treatment is TH for tropical environments.

Frequently asked questions

What is the AC-1 current rating of LC1F1400L7?

1400 A at ≤40 °C in AC-1 utilisation category (resistive loads). The conventional free-air thermal current (Ith) is also 1400 A at 40 °C.

What control voltage does LC1F1400L7 use?

208 V AC, 40-400 Hz. Pickup range is 0.85-1.1 Uc; dropout is 0.3-0.5 Uc at 55 °C. Inrush power is 2200 VA; hold-in consumption is 36 VA.

What compliance documentation does Schneider provide for LC1F1400L7?

The contactor carries certifications to EN 60947-1, EN 60947-4-1, IEC 60947-1, JIS C8201-4-1, IEC 60947-4-1, UL 60947-4-1, and CSA C22.2 No 60947-4-1. Rated insulation voltage is 1000 V (IEC/UL) and 1500 V (VDE 0110 Group C). Impulse withstand is 8 kV, overvoltage category III.

MPN