Skip to main content
Schneider Electric LC1F1400RD — Contactors

Schneider LC1F1400RD TeSys F Contactor, 1400 A AC-1, 440 VDC

MPNLC1F1400RD
Obsolete

Schneider Electric TeSys F, LC1F1400RD, 3-pole contactor, 1400 A AC-1, 440 VDC coil, plate mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LC1F1400RD — Identification
ParameterValue
Product / component typeContactor
Series / rangeTeSys
ApplicationResistive load
LC1F1400RD — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)<= 460 V DC
Utilisation categoryAC-1
LC1F1400RD — Contacts & Poles
ParameterValue
Pole configuration3P
LC1F1400RD — Environmental
ParameterValue
Operating altitude3000 m without derating
Protective treatment / pollution degreeTH
LC1F1400RD — Approvals
ParameterValue
StandardsEN 60947-4-1 EN 60947-1 JIS C8201-4-1 IEC 60947-1 IEC 60947-4-1 UL 60947-4-1 CSA C22.2 No 60947-4-1
LC1F1400RD — Mechanical
ParameterValue
Width438 mm
Height332 mm
Depth238.6 mm

Product details

The Schneider Electric LC1F1400RD is a 3-pole contactor from the TeSys F range, rated 1400 A conventional free-air thermal current (Ith) at 40 °C and 1400 A operational current in AC-1 utilisation category — meaning it's built for resistive loads like large heating banks or furnace elements, not motor starting (that would be AC-3). Control is via a 440 VDC coil with a 0.85–1.1 Uc pick-up range and a drop-out band of 0.3–0.5 Uc at 55 °C. It's a plate-mount unit, 332 mm tall, 438 mm wide, 238.6 mm deep — sized for a 100 x 5 mm busbar connection on the power side.

The 1400 A AC-1 rating is the headline number — it governs resistive load switching. The short-time withstand (Icw) profile tells you how long it can ride through a fault: 8000 A for 10 s, 6000 A for 30 s, 4500 A for 1 min, stepping down to 2600 A for 10 min. That's the curve for coordination with upstream protective devices. The associated fuse recommendation is 1600 A gG at ≤ 440 V. Heat dissipation runs 10 W holding, 150 W per pole under AC-1 load. Closing time is 50–60 ms, opening 45–60 ms.

Certified to IEC 60947-4-1, EN 60947-4-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, and JIS C8201-4-1. Rated insulation voltage 1000 V per IEC/UL, 1500 V per VDE 0110 group C. Impulse withstand voltage 8 kV, overvoltage category III. Protective treatment TH for tropical environments. Operating altitude 3000 m without derating.

Frequently asked questions

What is LC1F1400RD used for?

It is a 3-pole contactor rated 1400 A in AC-1 utilisation category, designed for resistive loads such as large heating banks, furnace elements, or other non-inductive switching. It is not rated for motor starting (AC-3 duty).

What compliance documentation does Schneider provide for LC1F1400RD?

The part carries certifications to IEC 60947-4-1, EN 60947-4-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, and JIS C8201-4-1. Rated insulation voltage is 1000 V per IEC/UL and 1500 V per VDE 0110 group C.

Where can I buy LC1F1400RD?

We source this end-of-life contactor to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm position.

MPN