Skip to main content
Schneider Electric LC1F1504GD — Contactors

TeSys F LC1F1504GD DC Contactor, 250 A AC-1, 125 VDC Coil

MPNLC1F1504GD
Obsolete

Schneider Electric TeSys F LC1F1504GD, 4-pole DC contactor, 250 A AC-1 at ≤440 V, 125 V DC coil, plate mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LC1F1504GD — Identification
ParameterValue
Product / component typeContactor
Series / rangeTeSys
ApplicationResistive load
LC1F1504GD — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)<= 460 V DC
Utilisation categoryAC-1
LC1F1504GD — Contacts & Poles
ParameterValue
Pole configuration4P
LC1F1504GD — Environmental
ParameterValue
IP degree of protectionIP2X front face with shrouds IEC 60529 IP2X front face with shrouds VDE 0106
Operating altitude9842.52 ft (3000 m) without derating
Protective treatment / pollution degreeTH
LC1F1504GD — Approvals
ParameterValue
StandardsEN 60947-4-1 JIS C8201-4-1 IEC 60947-1 EN 60947-1 IEC 60947-4-1
LC1F1504GD — Mechanical
ParameterValue
Width7.9 in (200.5 mm)
Height6.7 in (170 mm)
Depth6.7 in (171 mm)

Product details

The LC1F1504GD: The 250 A rated operational current (Ie) in AC-1 category at ≤440 V defines this contactor's capacity for resistive loads — heating elements, lighting banks, or transformer primaries. For motor loads (AC-3), the rating would be lower; this unit is not specified for AC-3 duty. The 125 V DC control circuit voltage (Uc) with an operational range of 0.85...1.1 Uc at 55 °C means the coil holds reliably between about 106 V and 138 V DC, and drops out between 0.15...0.2 Uc (19–25 V DC). Mechanical durability of 10 Mcycles gives a long service life in low-cycle applications.

This contactor mounts to a plate — not a DIN rail. The power circuit uses bolted connections, bar connections (2 x 25 x 3 mm), or ring terminals up to 120 mm². Control circuit wiring accepts screw clamp terminals for 1–4 mm² flexible or solid wire (without cable end) or 1–2.5 mm² with cable end. Tightening torque: control circuit 1.2 N·m, power circuit 18 N·m. The front face with shrouds achieves IP2X per IEC 60529 and VDE 0106. Dimensions: 170 mm height, 200.5 mm width, 171 mm depth.

The contactor is certified to IEC 60947-4-1, EN 60947-4-1, IEC 60947-1, EN 60947-1, and JIS C8201-4-1. Rated insulation voltage (Ui) is 1000 V per IEC 60947-4-1 or 1500 V per VDE 0110 group C. Overvoltage category III. Protective treatment TH for tropical environments. Storage temperature range: -60 to 80 °C.

Frequently asked questions

What is LC1F1504GD's listed depth (6.7 in (171 mm)) on this component line?

The depth is 6.7 in (171 mm).

What is LC1F1504GD's listed range (TeSys) on this component line?

The product belongs to the TeSys F range of contactors.

MPN
LC1F1504GD