Schneider Electric LC1F1700G7 — Contactors

Schneider Electric LC1F1700G7 TeSys F Contactor, 1700 A AC-1

MPNLC1F1700G7
Obsolete

Schneider Electric TeSys F, LC1F1700G7, 3-pole contactor, 1700 A AC-1, 120 VAC 40-400 Hz coil, plate mount.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

LC1F1700G7 — Identification
ParameterValue
Product / component typeContactor
Series / rangeTeSys
ApplicationResistive load

Ratings & Performance

LC1F1700G7 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)<= 460 V DC
Utilisation categoryAC-1

Contacts & Poles

LC1F1700G7 — Contacts & Poles
ParameterValue
Pole configuration3P

Environmental

LC1F1700G7 — Environmental
ParameterValue
Operating altitude3000 m without derating
Protective treatment / pollution degreeTH

Approvals

LC1F1700G7 — Approvals
ParameterValue
StandardsEN 60947-1 IEC 60947-4-1 IEC 60947-1 EN 60947-4-1 JIS C8201-4-1 UL 60947-4-1 CSA C22.2 No 60947-4-1

Mechanical

LC1F1700G7 — Mechanical
ParameterValue
Width438 mm
Height332 mm
Depth238.6 mm

Product details

1700 A AC-1 Power Contactor — Lifecycle & Fit

The Schneider Electric LC1F1700G7 is a TeSys F series 3-pole contactor rated for 1700 A conventional free-air thermal current (Ith) at 40 °C, with the same 1700 A figure as its AC-1 rated operational current (Ie) for resistive loads. That 1700 A number governs the real-world fit: this contactor is sized for heavy resistive heating banks, furnace elements, or large transformer primary switching — not motor starting, where the AC-3 derating would be substantially lower. The control circuit is 120 V AC, 40-400 Hz, with an inrush of 2200 VA and a hold-in draw of 36 VA.

Withstand & Breaking Capacity — Selectivity Headroom

The LC1F1700G7 carries a rated short-time withstand current (Icw) of 10,000 A for 10 seconds at 40 °C, stepping down to 7500 A for 30 s, 5500 A for 1 minute, 4200 A for 3 minutes, and 3000 A for 10 minutes. That 10 kA / 10 s figure is the one a site electrical engineer checks for coordination with upstream protection — it tells you the contactor can ride through a delayed fault long enough for the feeder breaker to clear, provided the let-through energy stays under the I²t curve. Rated breaking capacity is 2550 A per IEC 60947-4-1, and the associated fuse recommendation is 1600 A gG at ≤ 440 V.

Mounting & Termination — Panel Integration

Plate-mounted (not DIN-rail), with overall dimensions of 438 mm wide, 332 mm high, and 238.6 mm deep. Power circuit termination uses bar-type connectors accepting up to three cables per pole with a 100 x 5 mm busbar cross-section, torqued to 58 N·m. Control circuit wiring uses screw-clamp terminals accepting 1 to 4 mm² flexible or solid conductors, torqued to 1.2 N·m. The power pole contact composition is 3 NO.

Certified to IEC 60947-4-1, EN 60947-4-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, and JIS C8201-4-1. Rated insulation voltage (Ui) is 1000 V per IEC/UL 60947-4-1, with an impulse withstand voltage (Uimp) of 8 kV. Overvoltage category III. Protective treatment is TH for tropical environments.

Frequently asked questions

What is LC1F1700G7's listed depth?

The depth is 238.6 mm.

What compliance documentation does this brand provide for LC1F1700G7?

The LC1F1700G7 is certified to IEC 60947-4-1, EN 60947-4-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, and JIS C8201-4-1. Rated insulation voltage is 1000 V per IEC/UL 60947-4-1, with an impulse withstand voltage of 8 kV.