Schneider Electric LC1F1854X6 — Contactors

Schneider LC1F1854X6 TeSys F Contactor, 275 A AC-1, 4-Pole,

MPNLC1F1854X6
Obsolete

Schneider Electric TeSys F, LC1F1854X6, 4-pole contactor, 275 A AC-1 at ≤440 V, AC 60 Hz control, plate mount, end-of-life status.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LC1F1854X6 — Identification
ParameterValue
Product / component typeContactor
Series / rangeTeSys
ApplicationResistive load
LC1F1854X6 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)<= 690 V AC 50/60 Hz
Utilisation categoryAC-1
LC1F1854X6 — Contacts & Poles
ParameterValue
Pole configuration4P
LC1F1854X6 — Environmental
ParameterValue
IP degree of protectionIP2X front face with shrouds IEC 60529 IP2X front face with shrouds VDE 0106
Operating altitude9842.52 ft (3000 m) without derating
Protective treatment / pollution degreeTH
LC1F1854X6 — Approvals
ParameterValue
StandardsIEC 60947-1 EN 60947-4-1 IEC 60947-4-1 EN 60947-1 JIS C8201-4-1
LC1F1854X6 — Mechanical
ParameterValue
Width8.2 in (208.5 mm)
Height6.9 in (174 mm)
Depth7.1 in (181 mm)

Product details

The LC1F1854X6: The 275 A AC-1 rating at ≤440 V governs its use on resistive loads like heaters or lighting banks. For motor duty (AC-3), the power dissipation per pole is 12 W, versus 25 W per pole in AC-1 — the contactor runs cooler on motor loads but the AC-1 figure is the headline current limit. The control circuit is AC 60 Hz, with an operational voltage range of 0.85 to 1.1 Uc at 55 °C and a drop-out range of 0.35 to 0.55 Uc — the coil holds in at 600 V AC and drops out reliably below that band. Inrush power is 970 VA at 60 Hz; hold-in power is 66 VA. The coil suppression should match the AC line frequency; verify polarity if a free-wheel diode is added for DC switching. The contactor is plate-mounted (not DIN-rail), so panel integration requires a mounting plate or sub-panel. Dimensions are 7.1 in deep, 8.2 in wide, 6.9 in tall. Power circuit connections use bar or bolted lugs up to 150 mm²; control circuit terminals accept 1 to 4 mm² flexible or solid wire with screw clamp terminals. Tightening torque is 159.3 lbf·in for power and 10.6 lbf·in for control.

This contactor is sized for a 275 A resistive load at 440 V, so it typically lives in a power distribution or heating control panel on a mounting plate. Operating altitude is 3000 m without derating; storage temperature range is -60 to 80 °C.

Frequently asked questions

Who supplies LC1F1854X6 and how is it quoted?

The LC1F1854X6 is sourced through independent distribution channels and is quoted to order against an RFQ. Availability and current pricing are confirmed at quote time.

What are the key ratings of LC1F1854X6?

The LC1F1854X6 is a 4-pole contactor rated 275 A in AC-1 at ≤440 V, with a rated breaking capacity of 1480 A per IEC 60947-4-1. Control voltage is 600 V AC 60 Hz.

What standards does LC1F1854X6 comply with?

The LC1F1854X6 complies with IEC 60947-1, EN 60947-4-1, IEC 60947-4-1, EN 60947-1, and JIS C8201-4-1.

MPN
LC1F1854X6