Skip to main content
Schneider Electric LC1F185F722L — Contactors

Schneider LC1F185F722L TeSys F Contactor, 275 A AC-3, 110 VA

MPNLC1F185F722L
Obsolete

Schneider Electric TeSys F, 3-pole contactor, LC1F185F722L, 275 A AC-3 rated operational current, 110 V AC 50/60 Hz control coil, plate mount, end-of-life status.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

LC1F185F722L — Identification
ParameterValue
Product / component typeContactor
ApplicationMotor control Resistive load

Ratings & Performance

LC1F185F722L — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)<= 460 V DC
Utilisation categoryAC-3 AC-1

Contacts & Poles

LC1F185F722L — Contacts & Poles
ParameterValue
Pole configuration3P

Environmental

LC1F185F722L — Environmental
ParameterValue
IP degree of protectionIP2X front face with shrouds IEC 60529 IP2X front face with shrouds VDE 0106
Operating altitude9842.52 ft (3000 m) without derating
Mechanical robustnessVibrations contactor open2 Gn, 5...300 Hz Shocks contactor closed15 Gn for 11 ms Vibrations contactor closed5 Gn, 5...300 Hz Shocks contactor open7 Gn for 11 ms
Protective treatment / pollution degreeTH

Approvals

LC1F185F722L — Approvals
ParameterValue
StandardsJIS C8201-4-1 IEC 60947-1 IEC 60947-4-1 EN 60947-1 EN 60947-4-1

Mechanical

LC1F185F722L — Mechanical
ParameterValue
Width6.6 in (168.5 mm)
Height12.008 in (305 mm)
Depth7.1 in (181 mm)

Product details

TeSys F Contactor, 275 A AC-3 — End-of-Life Sourcing Note

The Schneider Electric LC1F185F722L is a TeSys F 3-pole contactor rated for 275 A at ≤ 440 V AC in AC-3 duty, meaning it switches motor loads up to that current — typically a 90 kW motor at 400 V or 125 hp at 460 V per UL/CSA. The 110 V AC 50/60 Hz control coil draws 970 VA inrush (60 Hz) and 55 VA holding.

The 275 A AC-3 rating governs motor switching; for resistive loads (AC-1), the contactor can handle higher currents — the power dissipation per pole is 12 W in AC-3 and 25 W in AC-1. The 110 V AC coil operates between 0.85 and 1.1 Uc (93.5–121 V) and drops out between 0.35 and 0.55 Uc (38.5–60.5 V). The contactor carries 2 NO + 2 NC auxiliary contacts built in.

Compliant with IEC 60947-1, IEC 60947-4-1, EN 60947-1, EN 60947-4-1, and JIS C8201-4-1. Rated insulation voltage is 1000 V per IEC 60947-4-1 and 1500 V per VDE 0110 group C. Overvoltage category III. The front face with shrouds provides IP2X protection per IEC 60529 and VDE 0106. Protective treatment is TH for tropical environments.

Plate-mounted (not DIN rail). Power circuit connections use bolted bars (2 bars 25 x 3 mm) or ring terminals up to 150 mm². Control circuit terminals accept 1–4 mm² solid or flexible wire (1–2.5 mm² with cable end). Tightening torque is 159.3 lbf·in (18 N·m) for power and 10.6 lbf·in (1.2 N·m) for control. Dimensions: 12.008 in (305 mm) height, 6.6 in (168.5 mm) width, 7.1 in (181 mm) depth.

The LC1F185F722L is classified as end-of-life (EOL) by the manufacturer. For BOM lines requiring this exact code, sourcing is through independent channels; we can quote availability and pricing against an RFQ. The associated fuse rating is 200 A aM or 315 A gG at ≤ 440 V.

Frequently asked questions

What are the key ratings of LC1F185F722L?

The LC1F185F722L is a 3-pole contactor rated 275 A at ≤ 440 V AC in AC-3 duty, with a 110 V AC 50/60 Hz control coil. It switches motors up to 90 kW at 400 V or 125 hp at 460 V (UL/CSA).

What compliance documentation does LC1F185F722L carry?

The LC1F185F722L complies with IEC 60947-1, IEC 60947-4-1, EN 60947-1, EN 60947-4-1, and JIS C8201-4-1. It carries IP2X front-face protection and TH protective treatment.

MPN