Skip to main content
Schneider Electric LC1F185KUE — Contactors

Schneider Electric LC1F185KUE TeSys F Contactor, 275 A AC-3,

MPNLC1F185KUE
Obsolete

Schneider Electric TeSys F series, LC1F185KUE, 3-pole contactor, 275 A rated operational current (AC-3 at ≤440 V), 100-250 V AC / 100-380 V DC control coil, plate mounting.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

LC1F185KUE — Identification
ParameterValue
Product / component typeContactor
Series / rangeTeSys
ApplicationResistive load Motor control

Ratings & Performance

LC1F185KUE — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)<= 690 V AC 50/60 Hz
Utilisation categoryAC-1 AC-3 AC-4

Contacts & Poles

LC1F185KUE — Contacts & Poles
ParameterValue
Pole configuration3P

Environmental

LC1F185KUE — Environmental
ParameterValue
Operating altitude3000 m without derating
Protective treatment / pollution degreeTH

Approvals

LC1F185KUE — Approvals
ParameterValue
StandardsEN/IEC 60947-1 EN/IEC 60947-4-1

Mechanical

LC1F185KUE — Mechanical
ParameterValue
Width168.5 mm
Height174 mm
Depth181 mm

Product details

The Schneider Electric LC1F185KUE is a 3-pole TeSys F contactor rated for 275 A in AC-3 duty at ≤440 V, meaning it switches motor loads up to that current under full load — the rating that governs real motor-starting applications, not just resistive heating. The control coil accepts 100-250 V AC 50/60 Hz or 100-380 V DC, with a PLC-compatible input per IEC 61131-2 Type 2. Built to EN/IEC 60947-4-1, the contactor is rated for both motor control (AC-3) and resistive loads (AC-1), with a rated breaking capacity of 1480 A and making capacity of 1850 A per the same standard — numbers that tell you it can interrupt a locked-rotor fault without welding contacts.

For AC-1 resistive use, the thermal current (Ith) is 275 A at 50 Hz with an average impedance of 0.33 mOhm, so heat dissipation runs 2.2-5.5 W total, or 25 W per pole in AC-1 and 12 W per pole in AC-3. That thermal budget matters in a sealed enclosure. Associated fuse protection: 315 A gG or 200 A aM at ≤440 V. The closing time spans 40-80 ms, opening 6-54 ms — a wide band, so coordination with upstream breakers needs to account for the slowest close.

Plate-mounted (not DIN-rail), so plan for a drilled backplate or sub-panel. Dimensions: 174 mm high, 168.5 mm wide, 181 mm deep. Power circuit connections accept bar (25 x 3 mm busbar), ring terminals up to 150 mm², or bolted connection — torque to 18 N·m. Control circuit uses screw-clamp terminals, 0.2-2.5 mm², torque to 0.6 N·m. The protective treatment is TH (tropicalized humidity resistance), and the part carries a standard 3 NO power pole configuration. For environments above 55 °C, derate the operational current — the 275 A figure is at ≤55 °C.

Frequently asked questions

What is the rated operational current of LC1F185KUE in AC-3 duty?

275 A at ≤440 V, ≤55 °C, per EN/IEC 60947-4-1. That is the motor-load rating. For AC-1 resistive loads, the thermal current Ith is also 275 A at 50 Hz.

What control coil voltage does LC1F185KUE accept?

100-250 V AC 50/60 Hz or 100-380 V DC. The operational limits are 85-275 V AC and 85-418 V DC at 55 °C. Drop-out occurs below 60 V AC or 45 V DC.

What standards does LC1F185KUE comply with?

EN/IEC 60947-1 and EN/IEC 60947-4-1. It is rated overvoltage category III and carries protective treatment TH for tropical environments.

Where can I buy LC1F185KUE and what is the lead time?

This part is sourced to order through independent distribution against an RFQ. Availability and current pricing are confirmed at quote time — submit an RFQ for a real ETA.

MPN
LC1F185KUE