Skip to main content
Schneider Electric LC1F185X6 — Contactors

Schneider Electric LC1F185X6 TeSys F Contactor, 185 A AC-3,

MPNLC1F185X6
Obsolete

Schneider Electric TeSys F contactor, LC1F185X6, 3-pole, 185 A AC-3 at ≤440 V, 90 kW at 400 V AC, AC 60 Hz control coil, plate mount, EOL lifecycle stage.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

LC1F185X6 — Identification
ParameterValue
Product / component typeContactor
Series / rangeTeSys
ApplicationResistive load Motor control

Ratings & Performance

LC1F185X6 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)<= 690 V AC 50/60 Hz
Utilisation categoryAC-3 AC-1 AC-4

Contacts & Poles

LC1F185X6 — Contacts & Poles
ParameterValue
Pole configuration3P

Environmental

LC1F185X6 — Environmental
ParameterValue
IP degree of protectionIP2X front face with shrouds IEC 60529 IP2X front face with shrouds VDE 0106
Operating altitude9842.52 ft (3000 m) without derating
Protective treatment / pollution degreeTH

Approvals

LC1F185X6 — Approvals
ParameterValue
StandardsIEC 60947-4-1 IEC 60947-1 JIS C8201-4-1 EN 60947-4-1 EN 60947-1

Mechanical

LC1F185X6 — Mechanical
ParameterValue
Width6.6 in (168.5 mm)
Height6.9 in (174 mm)
Depth7.1 in (181 mm)

Product details

TeSys F contactor — 185 A AC-3, end-of-life sourcing

The Schneider Electric LC1F185X6 is a 3-pole TeSys F contactor rated 185 A operational current in AC-3 duty at ≤440 V, switching motor loads up to 90 kW at 400 V AC 50/60 Hz. It carries a 275 A thermal current (Ith) at 50 Hz with an average impedance of 0.33 mOhm per pole, dissipating 12 W per pole in AC-3 and 25 W per pole in AC-1. The contactor is plate-mounted, IP2X on the front face with shrouds, and complies with IEC 60947-4-1, IEC 60947-1, EN 60947-4-1, and JIS C8201-4-1.

The 185 A AC-3 rating at ≤440 V governs motor switching — this contactor handles 90 kW at 400 V, 100 kW at 415 V, and 110 kW at 500 V. The AC-3 category means it is designed for starting and stopping squirrel-cage motors under load, not for jogging or plugging (that would be AC-4, where the rating drops to 33 kW at 400 V). The 275 A Ith (thermal current) covers resistive loads in AC-1 duty. The control coil is AC 60 Hz only, with a hold-in power of 66 VA at 60 Hz; the drop-out voltage range is 0.35...0.55 Uc, so verify your control supply stays within the operational limits of 0.85...1.1 Uc at 55 °C.

Plate-mounted — no DIN-rail clip. The power circuit uses bolted connections or ring terminals up to 150 mm²; torque to 159.3 lbf·in (18 N·m). Control circuit screw terminals accept 1...4 mm² flexible or solid wire, torque to 10.6 lbf·in (1.2 N·m). The contactor occupies a 168.5 mm width, 174 mm height, and 181 mm depth footprint on the plate.

Frequently asked questions

What is the closest alternative to LC1F185X6?

The closest peer in the TeSys F family is the LC1F185X4, which shares the same frame, AC-3 current rating, and motor power ratings but uses a 48...60 Hz control coil instead of the 60 Hz coil on the LC1F185X6. Verify control supply frequency before substituting.

Where can I buy LC1F185X6?

The LC1F185X6 is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time. Submit an RFQ for a firm offer.

MPN
LC1F185X6