Skip to main content
Schneider Electric LC1F2654L7 — Contactors

Schneider LC1F2654L7 TeSys F Contactor, 350 A AC-1, 208 V AC

MPNLC1F2654L7
Obsolete

Schneider Electric TeSys F LC1F2654L7, 4-pole contactor, 350 A AC-1 at ≤440 V, 208 V AC 40-400 Hz coil, plate mount, IP20 front face with shrouds.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LC1F2654L7 — Identification
ParameterValue
Product / component typeContactor
Series / rangeTeSys
ApplicationResistive load
LC1F2654L7 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)<= 460 V DC
Utilisation categoryAC-1
LC1F2654L7 — Contacts & Poles
ParameterValue
Pole configuration4P
LC1F2654L7 — Environmental
ParameterValue
IP degree of protectionIP20 front face with shrouds IEC 60529 IP20 front face with shrouds VDE 0106
Operating altitude9842.52 ft (3000 m) without derating
Protective treatment / pollution degreeTH
LC1F2654L7 — Approvals
ParameterValue
StandardsIEC 60947-1 IEC 60947-4-1 JIS C8201-4-1 EN 60947-4-1 EN 60947-1
LC1F2654L7 — Mechanical
ParameterValue
Width9.6 in (244.5 mm)
Height8.0 in (203 mm)
Depth8.4 in (213 mm)

Product details

The Schneider Electric LC1F2654L7 is a TeSys F 4-pole contactor rated for 350 A in AC-1 utilisation category (resistive load) at ≤440 V, 40 °C. The 208 V AC 40-400 Hz coil pulls 650 VA inrush, holds at 10 VA. This is a plate-mounted, open-style contactor — no enclosure, intended for panel integration where the installer provides the backplate and shrouds for IP20 front-face protection.

The 350 A AC-1 rating governs resistive loads like heaters or lighting banks. For motor duty (AC-3), the contactor would derate — the evidence does not list an AC-3 figure, so size it from the motor full-load current and the manufacturer's AC-3 table for the TeSys F frame. The 8 W heat dissipation (37 W per pole in AC-1) needs to be factored into the panel thermal budget — at full load the contactor dumps about 148 W total into the enclosure. Control circuit is AC 40-400 Hz, with a drop-out range of 0.15 to 0.2 Uc — meaning the coil releases when voltage falls to about 31-42 V on a 208 V nominal. The operating limits (0.85-1.1 Uc) ensure reliable pick-up even with line sag. The coil is screw-clamp terminated, accepting 1-4 mm² flexible or solid wire.

The contactor carries IEC 60947-1, IEC 60947-4-1, EN 60947-4-1, EN 60947-1, and JIS C8201-4-1 certification. Rated insulation voltage is 1000 V per IEC 60947-4-1 (1500 V per VDE 0110 group C). Overvoltage category III. Protective treatment TH (tropicalisation) is standard.

Mounting is plate (not DIN rail). Power circuit termination uses bolted bars or lugs accepting up to 240 mm² cable; tightening torque is 35 N·m on the power side. Control circuit uses screw-clamp terminals, 1.2 N·m. Dimensions: 8.0 in (203 mm) high, 9.6 in (244.5 mm) wide, 8.4 in (213 mm) deep. The IP20 front face requires the supplied shrouds to be fitted.

Frequently asked questions

What is the closest pin-compatible alternative to LC1F2654L7?

The evidence does not list a direct pin-compatible replacement. A parametric substitute from the TeSys F family would need to match the 350 A AC-1 rating, 4-pole NO configuration, plate mount, and 208 V AC coil. Contact us with your BOM for cross-reference support.

What compliance documentation does this brand provide for LC1F2654L7?

The contactor is certified to IEC 60947-1, IEC 60947-4-1, EN 60947-4-1, EN 60947-1, and JIS C8201-4-1. Rated insulation voltage is 1000 V (IEC) / 1500 V (VDE 0110 group C). Protective treatment TH (tropicalisation) is standard. RoHS/REACH documentation is typically available from Schneider's product compliance portal.

MPN
LC1F2654L7