Skip to main content
Schneider Electric LC1F4002ED — Contactors

Schneider LC1F4002ED TeSys F Contactor, 500 A AC-1, 48 V DC

MPNLC1F4002ED
Obsolete

Schneider Electric TeSys F LC1F4002ED contactor, 2-pole, 500 A AC-1 at ≤440 V, 48 V DC coil, plate mount, EOL hot lifecycle.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LC1F4002ED — Identification
ParameterValue
Product / component typeContactor
Series / rangeTeSys
ApplicationResistive load
LC1F4002ED — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)<= 460 V DC
Utilisation categoryAC-1
LC1F4002ED — Contacts & Poles
ParameterValue
Pole configuration2P
LC1F4002ED — Environmental
ParameterValue
IP degree of protectionIP20 front face with shrouds IEC 60529 IP20 front face with shrouds VDE 0106
Operating altitude9842.52 ft (3000 m) without derating
Protective treatment / pollution degreeTH
LC1F4002ED — Approvals
ParameterValue
StandardsEN 60947-4-1 EN 60947-1 JIS C8201-4-1 IEC 60947-4-1 IEC 60947-1
LC1F4002ED — Mechanical
ParameterValue
Width8.4 in (213 mm)
Height8.1 in (206 mm)
Depth8.6 in (219 mm)

Product details

The Schneider Electric LC1F4002ED is a TeSys F contactor rated for 500 A in AC-1 utilisation category at ≤440 V and 40 °C, with a 48 V DC standard control coil. This is a 2-pole normally-open contactor built for resistive load switching — think large heating banks, furnace elements, or DC power supplies where the load current is non-inductive and the contactor sees steady-state current rather than motor inrush.

Mounts to a plate (not DIN rail), so plan for a sub-panel or backplate with bolted connections. Power circuit uses bar connections (30 x 5 mm) or ring terminals up to 150 mm²; control circuit uses screw clamp terminals accepting 1–4 mm² flexible or solid wire. Tightening torque is 35 N.m on the power side and 1.2 N.m on the control side — a torque wrench is expected for the main lugs.

Rated insulation voltage is 1000 V per IEC 60947-4-1, with a rated breaking capacity of 3200 A conforming to the same standard. The contactor dissipates 6 W holding power and 65 W per pole under AC-1 load — factor that into your enclosure thermal budget. Associated fuse protection: 400 A aM or 500 A gG at ≤440 V.

Frequently asked questions

What is the closest alternative to LC1F4002ED in the TeSys F family?

No official successor order code is listed for the LC1F4002ED. A parametric alternative within the TeSys F range would need to match the 500 A AC-1 rating, 48 V DC coil, and 2-pole NO configuration — verify mounting and connection compatibility with your panel.

MPN
LC1F4002ED