Skip to main content
Schneider Electric LC1F4002N7 — Contactors

TeSys F LC1F4002N7 Contactor, 500 A AC-1, 415 V AC Coil, EOL

MPNLC1F4002N7
Obsolete

Schneider Electric TeSys F series, LC1F4002N7 contactor, 500 A AC-1 rated operational current, 415 V AC 40-400 Hz control circuit, 2 NO power poles, plate mount, EOL lifecycle.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LC1F4002N7 — Identification
ParameterValue
Product / component typeContactor
Series / rangeTeSys
ApplicationResistive load
LC1F4002N7 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)<= 460 V DC
Utilisation categoryAC-1
LC1F4002N7 — Contacts & Poles
ParameterValue
Pole configuration2P
LC1F4002N7 — Environmental
ParameterValue
IP degree of protectionIP20 front face with shrouds IEC 60529 IP20 front face with shrouds VDE 0106
Operating altitude9842.52 ft (3000 m) without derating
Protective treatment / pollution degreeTH
LC1F4002N7 — Approvals
ParameterValue
StandardsIEC 60947-4-1 JIS C8201-4-1 EN 60947-1 IEC 60947-1 EN 60947-4-1
LC1F4002N7 — Mechanical
ParameterValue
Width8.4 in (213 mm)
Height8.1 in (206 mm)
Depth8.6 in (219 mm)

Product details

TeSys F LC1F4002N7 — 500 A AC-1 Contactor, 415 V AC Coil

The Schneider Electric TeSys F LC1F4002N7 is a 2-pole contactor rated for 500 A in AC-1 utilisation category (resistive load) at up to 440 V AC, with a 415 V AC 40-400 Hz control coil. It is plate-mounted, carries a rated breaking capacity of 3200 A per IEC 60947-4-1, and dissipates 14 W holding power. The front face achieves IP20 protection with shrouds fitted.

Plate-mounted (not DIN rail). Power circuit connections use bar or bolted lugs — 30 x 5 mm bar or ring terminals up to 150 mm². Control circuit wiring is screw-clamp, accepting 1-4 mm² flexible or solid. Tightening torque is 35 Nm on the power side, 1.2 Nm on the control side. Operating altitude is 3000 m without derating; ambient storage range is -60 to 80 °C. The TH protective treatment indicates tropicalisation for humid environments.

Frequently asked questions

What is the rated operational current of LC1F4002N7?

The LC1F4002N7 is rated for 500 A in AC-1 utilisation category (resistive load) at up to 440 V AC, 40 °C ambient.

What control voltage does LC1F4002N7 use?

The control coil is rated 415 V AC, 40-400 Hz. Inrush is 1075 VA; holding power is 15 VA. Dropout occurs between 0.3 and 0.5 Uc (approximately 125-207 V).

What standards does LC1F4002N7 comply with?

It complies with IEC 60947-4-1, EN 60947-4-1, IEC 60947-1, EN 60947-1, and JIS C8201-4-1. Front-face IP20 protection with shrouds per IEC 60529 and VDE 0106.

Where can I buy LC1F4002N7?

As an end-of-life part, LC1F4002N7 is sourced through independent distribution. Submit an RFQ for current availability and pricing — confirmed at quote time.

MPN
LC1F4002N7