Skip to main content
Schneider Electric LC1F4004UD — Contactors

TeSys F LC1F4004UD 4-Pole DC Contactor, 500 A AC-1, 250 VDC

MPNLC1F4004UD
Obsolete

Schneider Electric TeSys F series, LC1F4004UD, 4-pole DC contactor, 500 A AC-1 rated operational current, 250 VDC control circuit, IP20 front face.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LC1F4004UD — Identification
ParameterValue
Product / component typeContactor
Series / rangeTeSys
ApplicationResistive load
LC1F4004UD — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)<= 460 V DC
Utilisation categoryAC-1
LC1F4004UD — Contacts & Poles
ParameterValue
Pole configuration4P
LC1F4004UD — Environmental
ParameterValue
IP degree of protectionIP20 front face with shrouds IEC 60529 IP20 front face with shrouds VDE 0106
Operating altitude9842.52 ft (3000 m) without derating
Protective treatment / pollution degreeTH
LC1F4004UD — Approvals
ParameterValue
StandardsEN 60947-1 EN 60947-4-1 IEC 60947-1 JIS C8201-4-1 IEC 60947-4-1
LC1F4004UD — Mechanical
ParameterValue
Width10.3 in (261 mm)
Height8.1 in (206 mm)
Depth8.6 in (219 mm)

Product details

TeSys F LC1F4004UD — 4-Pole DC Contactor, 500 A AC-1

The LC1F4004UD is a 4-pole DC-operated contactor from the Schneider TeSys F range, rated for 500 A in AC-1 (resistive load) duty at ≤440 V and ≤104 °F. That AC-1 rating governs the continuous current the main poles can carry through heating elements, ovens, or resistive banks — not motor starting. The 4 NO power pole configuration means all four poles close together on a DC coil pull-in. Control circuit is 250 V DC standard, with a hold-in power draw of 6 W at 68 °F and inrush of 1000 W during pickup. The dropout threshold sits at 20–35 % of Uc, so a sagging DC bus below about 50 V will release the armature cleanly — no partial engagement. Rated breaking capacity is 3200 A per IEC 60947-4-1, and the associated fuse recommendation is 400 A aM or 500 A gG at ≤440 V. That tells you the upstream short-circuit protection the contactor expects for type-2 coordination.

Mounting is plate-based — no DIN rail clip on this frame size. The footprint measures 10.3 in wide × 8.1 in tall × 8.6 in deep. Power connections use bar or ring terminals accepting up to 150 mm² cable; control circuit terminals take 1–4 mm² flexible or solid via screw clamp. Tightening torque for the power circuit is 309.8 lbf·in — substantial, so a torque wrench is expected in the panel shop. Front face carries IP20 protection with shrouds fitted. Operating altitude goes to 3000 m without derating. Storage temperature spans –76 to 176 °F, which covers most warehouse conditions but not extended outdoor exposure.

Certified to EN 60947-1, EN 60947-4-1, IEC 60947-1, IEC 60947-4-1, and JIS C8201-4-1. Overvoltage category III. Rated insulation voltage is 1000 V per IEC 60947-4-1 and 1500 V per VDE 0110 group C. Protective treatment is TH (tropicalized) for humid environments.

Frequently asked questions

What is the rated current of the LC1F4004UD?

500 A in AC-1 (resistive load) at ≤440 V and ≤104 °F. That is the continuous current rating for the main poles under resistive duty.

MPN
LC1F4004UD