Schneider Electric LC1F6304FE7 — Contactors

Schneider TeSys F LC1F6304FE7 Contactor, 1000 A AC-1, 115 VA

MPNLC1F6304FE7
Obsolete

Schneider Electric TeSys F series, LC1F6304FE7, 4-pole contactor, 1000 A AC-1, 115 V AC 50/60 Hz coil, plate mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LC1F6304FE7 — Identification
ParameterValue
Product / component typeContactor
Series / rangeTeSys
ApplicationResistive load
LC1F6304FE7 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)<= 460 V DC
Utilisation categoryAC-1
LC1F6304FE7 — Contacts & Poles
ParameterValue
Pole configuration4P
LC1F6304FE7 — Environmental
ParameterValue
IP degree of protectionIP20 front face with shrouds conforming to IEC 60529 IP20 front face with shrouds conforming to VDE 0106
Operating altitude3000 m without derating
Protective treatment / pollution degreeTH
LC1F6304FE7 — Approvals
ParameterValue
StandardsEN 60947-4-1 JIS C8201-4-1 IEC 60947-4-1 EN 60947-1 IEC 60947-1
LC1F6304FE7 — Mechanical
ParameterValue
Width389 mm
Height304 mm
Depth255 mm

Product details

The Schneider Electric TeSys F LC1F6304FE7 is a 4-pole power contactor rated for 1000 A in AC-1 utilisation category (resistive load) at up to 440 V AC, with a 115 V AC 50/60 Hz control coil. This is a heavy-duty, plate-mounted contactor sized for large resistive heating banks, furnace control, or distribution switching where the load current is continuous and non-inductive. The 4 NO power pole configuration means all four poles close together — no built-in auxiliary contacts, so plan for an external auxiliary block if you need status feedback to the PLC.

The headline number is 1000 A at ≤440 V AC in AC-1. AC-1 covers resistive loads — heaters, ovens, incandescent lighting — where the current inrush is near the steady-state value. Do not apply this contactor to motor starting (AC-3) or mixed loads without derating; the TeSys F range has separate AC-3 rated variants for that duty. The 115 V AC coil holds between 0.85 and 1.1 Uc and drops out between 0.25 and 0.5 Uc — verify your control transformer sizing, especially if the line voltage sags under heavy load. The 20 W heat dissipation at rated current means the panel ventilation must clear that thermal load; plate mounting on a steel backplate helps conduct heat away.

Plate-mounted — no DIN rail clip. The power circuit uses bar-type terminals accepting up to 60 x 5 mm busbars, typical for 1000 A class switchgear. Control circuit wiring is screw-clamp, 1 to 4 mm² flexible or solid. Tightening torque: 58 N.m on the power connections, 1.2 N.m on the control circuit. The IP20 front face with shrouds meets IEC 60529 and VDE 0106 for finger-safe front-of-panel access, but the rear terminals are live when the contactor is closed — enclosure required.

Designed and tested to IEC 60947-4-1, EN 60947-4-1, and JIS C8201-4-1. The rated insulation voltage is 1000 V per IEC 60947-4-1, 1500 V per VDE 0110 group C. Impulse withstand voltage is 8 kV, overvoltage category III — suitable for fixed-installation distribution panels. The TH protective treatment indicates tropicalisation for humid environments.

Frequently asked questions

Where can I buy LC1F6304FE7 and what is the lead time?

We source this end-of-life contactor through our independent distribution network. It is quoted to order against an RFQ; availability and current pricing are confirmed at quote time. Submit an RFQ for a firm lead-time estimate.

What is the rated operational current of LC1F6304FE7?

1000 A in AC-1 utilisation category at ≤440 V AC, at an ambient temperature below 40 °C. This is a resistive-load rating; do not apply at this current level for motor or inductive loads without consulting the AC-3 derating curve.

What is the control coil voltage for LC1F6304FE7?

115 V AC, 40 to 400 Hz. The coil operates between 0.85 and 1.1 Uc and drops out between 0.25 and 0.5 Uc at 55 °C.

What compliance standards does LC1F6304FE7 meet?

The contactor is designed to IEC 60947-4-1, EN 60947-4-1, and JIS C8201-4-1. Rated insulation voltage is 1000 V per IEC 60947-4-1 and 1500 V per VDE 0110 group C. Impulse withstand is 8 kV, overvoltage category III.

MPN