Skip to main content
Schneider Electric LC1F78041 — Contactors

TeSys F LC1F78041 Contactor Body, 4P 1600 A AC-1, EOL

MPNLC1F78041
Obsolete

Schneider Electric TeSys F contactor body, LC1F78041, 4P (4 NO), AC-1 rated 1600 A at 40 °C, without coil, EOL phase-out.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LC1F78041 — Identification
ParameterValue
Product / component typeContactor
Series / rangeTeSys
ApplicationResistive load
LC1F78041 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)<= 460 V DC
Utilisation categoryAC-1
LC1F78041 — Contacts & Poles
ParameterValue
Pole configuration4P
LC1F78041 — Environmental
ParameterValue
IP degree of protectionIP20 front face with shrouds IEC 60529 IP20 front face with shrouds VDE 0106
Operating altitude9842.52 ft (3000 m) without derating
Mechanical robustnessVibrations contactor open2.5 Gn, 5...300 Hz Vibrations contactor closed5.5 Gn, 5...300 Hz Shocks contactor open5 Gn for 1/2 sine wave (11 ms) Shocks contactor closed15 Gn for 1/2 sine wave (11 ms)
Protective treatment / pollution degreeTH
LC1F78041 — Approvals
ParameterValue
StandardsEN 60947-4-1 JIS C8201-4-1 IEC 60947-1 IEC 60947-4-1 EN 60947-1
LC1F78041 — Mechanical
ParameterValue
Width33.9 in (862 mm)
Height17.09 in (434 mm)
Depth9.8 in (250 mm)

Product details

The Schneider Electric TeSys F LC1F78041 is a 4-pole (4 NO) contactor body rated for AC-1 resistive loads at 1600 A per phase (1000 A on the neutral pole) up to 1000 V AC, 40 °C ambient. It's a plate-mount unit — 250 mm deep, 862 mm wide, 434 mm tall — designed for high-current switching in industrial power distribution and heavy resistive heating banks. No coil included; you pair it with a separate TeSys F coil block.

Power circuit torque is 58 N.m. Rated short-time withstand current (Icw) is 6250 A for 10 s — that's the fault-ride-through capability for selective coordination downstream. The making capacity hits 7800 A AC, and the breaking capacity is 6240 A per IEC 60947-4-1. Overvoltage category III and impulse withstand of 8 kV mean it's rated for fixed-installation mains-level transients. Operating altitude goes to 3000 m without derating, which covers most high-altitude plant sites.

The LC1F78041 carries IEC 60947-1, IEC 60947-4-1, EN 60947-1, EN 60947-4-1, and JIS C8201-4-1. That covers the contactor standard for motor starters and switching devices. Protective treatment is TH (tropicalized) for humid environments. Mechanical durability is 5 million cycles — a heavy-duty industrial lifespan for a contactor this size.