Skip to main content
Schneider Electric LC1G3304BEEA

Schneider LC1G3304BEEA TeSys Giga Contactor, 330A AC-3

MPNLC1G3304BEEA
Active

Schneider Electric, TeSys Giga series, LC1G3304BEEA, 4-pole contactor, 330 A AC-3, 24...48 V AC/50 Hz DC, dark grey.

$2,410.00 – $2,686.52Ref. price · indicative, final on quote
StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

LC1G3304BEEA key specifications
ParameterValue
Range of productTeSys Giga
Product or component typeContactor
Coil voltage24...48 V AC 50/60 Hz 24...48 V DC
Voltage1000 V
Control circuit voltage limitsOperational: 0.8 Uc Min...1.1 Uc Max (at Drop-out: 0.1 Uc Max...0.45 Uc Min (at <140 °F (60 °C))
[Ue] rated operational voltage<= 460 V DC
[Uimp] rated impulse withstand voltage8 kV
[Icw] rated short-time withstand current2.65 kA - 10 s 1.8 kA - 30 s 1.3 kA - 1 min 0.9 kA - 3 min 0.75 kA - 10 min
Breaking capacity2940 A at 440 V
[Ie] rated operational current330 A (at 440 A (at <104 °F (40 °C)) at <= 1000 V AC-1
[Ith] conventional free air thermal current440 A (at 104 °F (40 °C))
Inrush power in380 W

All specifications

LC1G3304BEEA additional specifications
ParameterValue
Power dissipation per pole30 W AC-1 - Ith 440 A 16 W AC-3 - Ith 330 A
Inrush power in VA (50/60 hz, AC)540 VA
Hold-in power consumption in6.4 W
Poles description4P
Pole contact composition4 NO
Utilisation categoryAC-3 AC-3e AC-1 AC-5a AC-5b AC-6a AC-6b DC-1 DC-3 DC-5
IP degree of protectionIP2X front face with shrouds IEC 60529 IP2X front face with shrouds VDE 0106
Mounting supportPlate
Connection pitch1.8 in (45 mm)
Connections - terminalsPower circuit: bar 2 - busbar cross section: 32 x 10 mm Power circuit: lugs-ring terminals 1 0.3 in² (185 mm²) Power circuit: bolted connection Control circuit: push-in 1 0.0003...0.004 in² (0.2...2.5 mm²) - cable stiffness: solid stranded without cable end Control circuit: push-in 1 0.0004...0.004 in² (0.25...2.5 mm²) - cable stiffness: flexible with cable end Control circuit: push-in 2 0.0008...0.002 in² (0.5...1.0 mm²) with cable end Control circuit: push-in 0.001...0.004 in² (0.75...2.5 mm²) - cable stiffness: solid stranded without cable end Control circuit: push-in 0.001...0.004 in² (0.75...2.5 mm²) - cable stiffness: flexible with cable end
ColorDark grey
Depth8.9 in (226 mm)
Width7.3 in (185 mm)
Height11.4 in (290 mm)
Mechanical durability8 Mcycles
StandardsEN/IEC 60947-4-1 EN/IEC 60947-5-1 UL 60947-4-1 CSA C22.2 No 60947-4-1 JIS C8201-4-1 JIS C8201-5-1 UL 60335-1 UL 60335-2-40:Annex JJ
RangeTeSys
CategoryUS10I1222329
Operating time40...70 ms closing 15...50 ms opening
Coil technologyBuilt-in bidirectional peak limiting
Average impedance0.000144 Ohm
Device short nameLC1G
Tightening torque309.8 lbf.in (35 N.m)
Compatibility codeLC1G
Overvoltage categoryIII
Protective treatmentTH
Contactor applicationPower switching
Mechanical robustnessVibrations 5...300 Hz 2 gn contactor open Vibrations 5...300 Hz 4 gn contactor closed Shocks 10 gn 11 ms contactor open Shocks 15 gn 11 ms contactor closed
Associated fuse rating400 A aM at 250 A aM at 500 A gG at 600 A UL Type L at <= 600 V
Maximum operating rate600 cyc/h AC-3 600 cyc/h AC-3e 300 cyc/h AC-1
Safety reliability levelB10d = 400000 cycles contactor with nominal load EN/ISO 13849-1 B10d = 3000000 cycles contactor with mechanical load EN/ISO 13849-1
Irms rated making capacity1560 A at 440 V
Auxiliary contact composition1 NO + 1 NC
Ambient air temperature for storage-76...176 °F (-60...80 °C)
Ambient air temperature for operation-13...140 °F (-25...60 °C)
Permissible ambient air temperature around the device-40...158 °F (-40...70 °C) at Uc

Product details

The Schneider LC1G3304BEEA is a TeSys Giga 4-pole contactor for AC-3 motor switching with a 24...48 V AC/DC coil and built-in bidirectional peak limiting. It carries UL, IEC, and CSA approvals per EN/IEC 60947-4-1.

AC-3 Duty and Thermal Management

The AC-3 rating of 330 A is the motor-switching current; the contactor also handles 440 A in AC-1 resistive duty. Power dissipation runs 16 W per pole under AC-3 and 30 W per pole under AC-1 at full thermal current, so panel ventilation and busbar sizing need to account for that heat. The coil technology uses built-in bidirectional peak limiting, meaning no external snubber is needed for standard transient suppression; the coil holds in at 0.8 Uc and drops out between 0.1 and 0.45 Uc depending on temperature.

The contactor mounts on a plate, not DIN rail. Power terminals accept bar or ring lugs up to 185 mm²; busbar cross-section up to 32 x 10 mm. Tightening torque is 35 N.m on the power connections. Control circuit uses push-in terminals for 0.2 to 2.5 mm² stranded or solid wire. Overall dimensions: 290 mm high, 185 mm wide, 226 mm deep. Mechanical durability is 8 million cycles; maximum operating rate for AC-3 is 600 cycles per hour. The contactor meets vibration and shock levels typical for industrial enclosures: 2 gn open, 4 gn closed (vibration), 10 gn open, 15 gn closed (shock). For functional safety applications, B10d values are 400,000 cycles under nominal load and 3,000,000 cycles with mechanical load per EN/ISO 13849-1.

MPN
LC1G3304BEEA