Skip to main content
Schneider Electric LC1G3304EHEA

TeSys Giga LC1G3304EHEA Contactor, 48-130 V AC/DC

MPNLC1G3304EHEA
Active

Schneider Electric TeSys Giga LC1G3304EHEA, 4-pole contactor, 48-130 V AC/DC coil, power switching, 300 hp at 600 V.

$2,410.00 – $2,849.28Ref. price · indicative, final on quote
StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

LC1G3304EHEA key specifications
ParameterValue
Range of productTeSys Giga
Product or component typeContactor
Coil voltage48...130 V AC 50/60 Hz 48...130 V DC
Voltage1000 V
Control circuit voltage limitsOperational: 0.8 Uc Min...1.1 Uc Max (at Drop-out: 0.1 Uc Max...0.45 Uc Min (at <140 °F (60 °C))
[Ue] rated operational voltage<= 460 V DC
[Uimp] rated impulse withstand voltage8 kV
[Icw] rated short-time withstand current2.65 kA - 10 s 1.8 kA - 30 s 1.3 kA - 1 min 0.9 kA - 3 min 0.75 kA - 10 min
Breaking capacity2940 A at 440 V
[Ie] rated operational current330 A (at 440 A (at <104 °F (40 °C)) at <= 1000 V AC-1
[Ith] conventional free air thermal current440 A (at 104 °F (40 °C))
Inrush power in360 W

All specifications

LC1G3304EHEA additional specifications
ParameterValue
Maximum horse power rating100 hp at 200/208 V 60 Hz 125 hp at 230/240 V 60 Hz 250 hp at 460/480 V 60 Hz 300 hp at 575/600 V 60 Hz
Power dissipation per pole30 W AC-1 - Ith 440 A 16 W AC-3 - Ith 330 A
Inrush power in VA (50/60 hz, AC)430 VA
Hold-in power consumption in9.0 W
Poles description4P
Pole contact composition4 NO
Utilisation categoryAC-3 AC-3e AC-1 AC-5a AC-5b AC-6a AC-6b DC-1 DC-3 DC-5
IP degree of protectionIP2X front face with shrouds IEC 60529 IP2X front face with shrouds VDE 0106
Mounting supportPlate
Connection pitch1.8 in (45 mm)
Connections - terminalsPower circuit: bar 2 - busbar cross section: 32 x 10 mm Power circuit: lugs-ring terminals 1 0.3 in² (185 mm²) Power circuit: bolted connection Control circuit: push-in 1 0.0003...0.004 in² (0.2...2.5 mm²) - cable stiffness: solid stranded without cable end Control circuit: push-in 1 0.0004...0.004 in² (0.25...2.5 mm²) - cable stiffness: flexible with cable end Control circuit: push-in 2 0.0008...0.002 in² (0.5...1.0 mm²) with cable end Control circuit: push-in 0.001...0.004 in² (0.75...2.5 mm²) - cable stiffness: solid stranded without cable end Control circuit: push-in 0.001...0.004 in² (0.75...2.5 mm²) - cable stiffness: flexible with cable end
ColorDark grey
Depth8.9 in (226 mm)
Width7.3 in (185 mm)
Height11.4 in (290 mm)
Mechanical durability8 Mcycles
StandardsEN/IEC 60947-4-1 EN/IEC 60947-5-1 UL 60947-4-1 CSA C22.2 No 60947-4-1 JIS C8201-4-1 JIS C8201-5-1 UL 60335-1 UL 60335-2-40:Annex JJ
RangeTeSys
CategoryUS10I1222329
Operating time40...70 ms closing 15...50 ms opening
Coil technologyBuilt-in bidirectional peak limiting
Average impedance0.000144 Ohm
Device short nameLC1G
Tightening torque309.8 lbf.in (35 N.m)
Compatibility codeLC1G
Overvoltage categoryIII
Protective treatmentTH
Contactor applicationPower switching
Mechanical robustnessVibrations 5...300 Hz 2 gn contactor open Vibrations 5...300 Hz 4 gn contactor closed Shocks 10 gn 11 ms contactor open Shocks 15 gn 11 ms contactor closed
Associated fuse rating400 A aM at 250 A aM at 500 A gG at 600 A UL Type L at <= 600 V
Maximum operating rate600 cyc/h AC-3 600 cyc/h AC-3e 300 cyc/h AC-1
Safety reliability levelB10d = 400000 cycles contactor with nominal load EN/ISO 13849-1 B10d = 3000000 cycles contactor with mechanical load EN/ISO 13849-1
Irms rated making capacity3830 A at 440 V
Auxiliary contact composition1 NO + 1 NC
Ambient air temperature for storage-76...176 °F (-60...80 °C)
Ambient air temperature for operation-13...140 °F (-25...60 °C)
Permissible ambient air temperature around the device-40...158 °F (-40...70 °C) at Uc

Product details

Control voltage and coil technology

Utilisation categories and power ratings

Rated for AC-3, AC-3e, AC-1, AC-5a, AC-5b, AC-6a, AC-6b, DC-1, DC-3, and DC-5 – this contactor covers motor starting, resistive, and DC load switching. At 460/480 V 60 Hz it handles 250 hp; at 575/600 V, 300 hp. The AC-1 thermal current (Ith) is 440 A per pole, dissipating 30 W per pole.

Mechanical durability and robustness

Mechanical life is 8 million cycles. The contactor withstands vibration up to 4 gn (closed) and shock 15 gn for 11 ms (closed), making it suitable for high-vibration environments like compressors or conveyors.

Listed as current production. No end-of-life notice or phase-out indicated. The part is specified into the BOM and available to quote against a purchase order through our distribution channel.

Meets EN/IEC 60947-4-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, and JIS C8201-4-1. Also listed for UL 60335-1 and UL 60335-2-40 Annex JJ for appliance applications. IP2X front face with shrouds.

Frequently asked questions

What is the listed color of the LC1G3304EHEA?

Dark grey.

What is the depth of the LC1G3304EHEA?

226 mm (8.9 in).

What compliance standards does the LC1G3304EHEA meet?

EN/IEC 60947-4-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, JIS C8201-4-1, UL 60335-1, and UL 60335-2-40 Annex JJ.

MPN
LC1G3304EHEA