Schneider Electric LC1G500LSEA
MPNLC1G500LSEA
Active
HIGH POWER CONTACTOR TESYS GIGA 3 POLE 3NO AC-3 440V 500|HIGH POWER CONTACTOR TESYS GIGA 3 POLE 3NO AC-3 440V 500A ADVANCED VERSION 200 500V WIDE BAND AC/DC COIL
$963.93Ref. price · indicative, final on quote
StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →Specifications
| Parameter | Value |
|---|---|
| Range of product | TeSys Giga |
| Product or component type | Contactor |
| Coil voltage | 200...500 V AC 50/60 Hz 200...500 V DC |
| Voltage | 1000 V |
| Control circuit voltage limits | Operational: 0.8 Uc Min...1.1 Uc Max (at Drop-out: 0.1 Uc Max...0.45 Uc Min (at <140 °F (60 °C)) |
| [Ue] rated operational voltage | <= 460 V DC |
| [Uimp] rated impulse withstand voltage | 8 kV |
| [Icw] rated short-time withstand current | 4.0 kA - 10 s 2.8 kA - 30 s 2.2 kA - 1 min 1.5 kA - 3 min 1.2 kA - 10 min |
| Breaking capacity | 4600 A at 440 V |
| [Ie] rated operational current | 700 A (at 500 A (at <140 °F (60 °C)) at <= 440 V AC-3 |
| Motor power | 147 kW at 230 V AC 50/60 Hz (AC-3e) 250 kW at 400 V AC 50/60 Hz (AC-3e) 250 kW at 415 V AC 50/60 Hz (AC-3e) 280 kW at 440 V AC 50/60 Hz (AC-3e) 315 kW at 500 V AC 50/60 Hz (AC-3e) 355 kW at 690 V AC 50/60 Hz (AC-3e) 335 kW at 1000 V AC 50/60 Hz (AC-3e) 160 kW at 230 V AC 50/60 Hz (AC-3) 250 kW at 400 V AC 50/60 Hz (AC-3) 250 kW at 415 V AC 50/60 Hz (AC-3) 315 kW at 440 V AC 50/60 Hz (AC-3) 355 kW at 500 V AC 50/60 Hz (AC-3) 355 kW at 690 V AC 50/60 Hz (AC-3) 335 kW at 1000 V AC 50/60 Hz (AC-3) 150 kW at 230 V AC 50/60 Hz (AC-4) 250 kW at 400 V AC 50/60 Hz (AC-4) 250 kW at 415 V AC 50/60 Hz (AC-4) 295 kW at 440 V AC 50/60 Hz (AC-4) 295 kW at 500 V AC 50/60 Hz (AC-4) 355 kW at 690 V AC 50/60 Hz (AC-4) 280 kW at 1000 V AC 50/60 Hz (AC-4) |
| Inrush power in | 300 W |
All specifications
| Parameter | Value |
|---|---|
| Maximum horse power rating | 150 hp at 200/208 V 60 Hz 200 hp at 230/240 V 60 Hz 400 hp at 460/480 V 60 Hz 450 hp at 575/600 V 60 Hz |
| Power dissipation per pole | 40 W AC-1 - Ith 700 A 20 W AC-3 - Ith 500 A |
| Inrush power in VA (50/60 hz, AC) | 535 VA |
| Hold-in power consumption in | 8.6 W |
| Poles description | 3P |
| Pole contact composition | 3 NO |
| Utilisation category | AC-1 AC-3 AC-3e AC-4 AC-5a AC-5b AC-6a AC-6b AC-8b AC-8a DC-1 DC-3 DC-5 |
| IP degree of protection | IP2X front face with shrouds IEC 60529 IP2X front face with shrouds VDE 0106 |
| Mounting support | Plate |
| Connection pitch | 1.8 in (45 mm) |
| Connections - terminals | Power circuit: bar 2 - busbar cross section: 32 x 10 mm Power circuit: lugs-ring terminals 1 0.3 in² (185 mm²) Power circuit: bolted connection Control circuit: push-in 1 0.0003...0.004 in² (0.2...2.5 mm²) - cable stiffness: solid stranded without cable end Control circuit: push-in 1 0.0004...0.004 in² (0.25...2.5 mm²) - cable stiffness: flexible with cable end Control circuit: push-in 2 0.0008...0.002 in² (0.5...1.0 mm²) with cable end Control circuit: push-in 0.001...0.004 in² (0.75...2.5 mm²) - cable stiffness: solid stranded without cable end Control circuit: push-in 0.001...0.004 in² (0.75...2.5 mm²) - cable stiffness: flexible with cable end |
| Color | Dark grey |
| Depth | 8.9 in (226 mm) |
| Width | 5.5 in (140 mm) |
| Height | 11.4 in (290 mm) |
| Mechanical durability | 8 Mcycles |
| Standards | EN/IEC 60947-4-1 EN/IEC 60947-5-1 UL 60947-4-1 CSA C22.2 No 60947-4-1 JIS C8201-4-1 JIS C8201-5-1 IEC 60335-1:Clause 30.2 IEC 60335-2-40:Annex JJ UL 60335-1 UL 60335-2-40:Annex JJ |
| Range | TeSys |
| Category | US10I1222329 |
| Operating time | 40...70 ms closing 15...50 ms opening |
| Coil technology | Built-in bidirectional peak limiting |
| Average impedance | 0.00008 Ohm |
| Device short name | LC1G |
| Tightening torque | 309.8 lbf.in (35 N.m) |
| Compatibility code | LC1G |
| Overvoltage category | III |
| Protective treatment | TH |
| Contactor application | Power switching Motor control |
| Mechanical robustness | Vibrations 5...300 Hz 2 gn contactor open Vibrations 5...300 Hz 4 gn contactor closed Shocks 10 gn 11 ms contactor open Shocks 15 gn 11 ms contactor closed |
| Associated fuse rating | 500 A aM at 400 A aM at 800 A gG at 600 A UL Type L at <= 600 V |
| Maximum operating rate | 600 cyc/h AC-3 600 cyc/h AC-3e 300 cyc/h AC-1 150 cyc/h AC-4 |
| Safety reliability level | B10d = 400000 cycles contactor with nominal load EN/ISO 13849-1 B10d = 3000000 cycles contactor with mechanical load EN/ISO 13849-1 |
| Auxiliary contact composition | 1 NO + 1 NC |
| Ambient air temperature for storage | -76...176 °F (-60...80 °C) |
| Ambient air temperature for operation | -13...140 °F (-25...60 °C) |
| Permissible ambient air temperature around the device | -40...158 °F (-40...70 °C) at Uc |
MPN