Skip to main content
Schneider Electric LC1K06013Q7 — Contactors

TeSys K LC1K06013Q7 Contactor, 3P, AC-3 6 A, 380-400 V AC Co

MPNLC1K06013Q7
Active

Schneider Electric TeSys K contactor, LC1K06013Q7, 3P, AC-3 ≤440 V 6 A, 1 NC aux, 380-400 V AC coil, 1.5-3 kW motor power.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

LC1K06013Q7 — Identification
ParameterValue
Product / component typeContactor
Series / rangeTeSys
LC1K06013Q7 — Ratings & Performance
ParameterValue
Utilisation categoryAC-4 AC-3
LC1K06013Q7 — Contacts & Poles
ParameterValue
Pole configuration3P
LC1K06013Q7 — Environmental
ParameterValue
Flame retardanceV1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102
LC1K06013Q7 — Mechanical
ParameterValue
Width45 mm
Height58 mm
Depth57 mm

Product details

The Schneider Electric TeSys K LC1K06013Q7 is a three-pole contactor rated for AC-3 and AC-4 utilisation categories, meaning it is built for switching motor loads under full load and plugging/inching duty. Its rated operational current is 6 A at ≤440 V AC in AC-3 service, which translates to motor power handling of 1.5 kW at 220-230 V AC, 2.2 kW at 380-415 V AC, and 3 kW across the 440-690 V AC range — covering common global voltage bands without a derate step at the top end.

Mounting and integration into a panel

The contactor measures 45 mm wide by 58 mm tall by 57 mm deep — a compact footprint that fits standard 45 mm DIN-rail spacing and leaves a 57 mm gutter depth for wiring. The three NO main poles and one NC auxiliary contact are clearly labelled on the moulding; the auxiliary is wired separately via a screw terminal.

Short-circuit withstand and fault handling

The power circuit can withstand 90 A for 1 second, 80 A for 10 seconds, and 45 A for 1 minute — these ratings define how long the contactor can carry fault current before the upstream protection must clear. For the signalling circuit (the auxiliary), the withstand is 90 A for 500 ms and 110 A for 100 ms. These numbers matter when coordinating with a motor circuit protector or fuse: the contactor should not be the weak link in a short-circuit event.

Frequently asked questions

What motor power can this contactor switch?

It handles 1.5 kW at 220-230 V AC, 2.2 kW at 380-415 V AC, and 3 kW at 440-690 V AC, all at 50/60 Hz.

What is the coil voltage?

380-400 V AC, 50/60 Hz.

Does this contactor have an auxiliary contact?

Yes, one normally-closed (NC) auxiliary contact is included.

MPN
LC1K06013Q7