Skip to main content
Schneider Electric LC1K06016L7 — Contactors

Schneider LC1K06016L7 TeSys K Contactor, 6A AC-3, 200-208V C

MPNLC1K06016L7
Active

Schneider TeSys K contactor, 3P, AC-3 <= 440 V 6 A, 1 NC aux., 200...208 V AC coil, obsolete.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LC1K06016L7 — Identification
ParameterValue
Product / component typeContactor
Series / rangeTeSys
LC1K06016L7 — Ratings & Performance
ParameterValue
Utilisation categoryAC-4 AC-3
LC1K06016L7 — Contacts & Poles
ParameterValue
Pole configuration3P
LC1K06016L7 — Environmental
ParameterValue
Flame retardanceV1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102
LC1K06016L7 — Mechanical
ParameterValue
Width45 mm
Height58 mm
Depth57 mm
LC1K06016L7 — Other specifications
ParameterValue
Motor power1.5 kW at 220...230 V AC 50/60 Hz 2.2 kW at 380...415 V AC 50/60 Hz 3 kW at 440 V AC 50/60 Hz 3 kW at 480 V AC 50/60 Hz 3 kW at 500...600 V AC 50/60 Hz 3 kW at 660...690 V AC 50/60 Hz
Heat dissipation1.3 W
Range of productTeSys K
Device short nameLC1K
Compatibility codeLC1K
Device applicationControl
Pole contact composition3 NO
[Ie] rated operational current6 A at 10 MOhm for signalling circuit
[Icw] rated short-time withstand current90 A 50 °C - 1 s for power circuit 85 A 50 °C - 5 s for power circuit 80 A 50 °C - 10 s for power circuit 60 A 50 °C - 30 s for power circuit 45 A 50 °C - 1 min for power circuit 40 A 50 °C - 3 min for power circuit 20 A 50 °C - >= 15 min for power circuit 80 A - 1 s for signalling circuit 90 A - 500 ms for signalling circuit 110 A - 100 ms for signalling circuit

Product details

The LC1K06016L7 is a Schneider TeSys K three-pole contactor rated for AC-3 duty at 6 A up to 440 V, with a 200...208 V AC coil and one normally closed auxiliary contact. It switches motor loads up to 1.5 kW at 220-230 V, 2.2 kW at 380-415 V, or 3 kW at 440-690 V — the higher voltage ranges let it handle the same motor current at a lower line draw. The 1.3 W heat dissipation stays low enough that it won't cook neighbouring components in a crowded panel.

For a BOM freeze or line-down replacement, the closest functional match in the TeSys K family shares the same 45 mm width and 58 mm height footprint, but verify the coil voltage and auxiliary configuration against your panel wiring.

Frequently asked questions

What are the key ratings for this contactor?

Rated operational current is 6 A in AC-3 duty up to 440 V. Motor power ranges from 1.5 kW at 220-230 V up to 3 kW at 440-690 V. The coil is 200-208 V AC. Short-time withstand current is 90 A for 1 second on the power circuit.

What is the physical size of the LC1K06016L7?

It is 45 mm wide, 58 mm high, and 57 mm deep — a standard compact DIN-rail contactor footprint.

What compliance documentation is available for this part?

The contactor carries UL 94 V1 flame retardance rating and conforms to NF F 16-101 and NF F 16-102 for rail applications. Standard Schneider documentation for the TeSys K series covers RoHS and REACH compliance.

MPN
LC1K06016L7