Skip to main content
Schneider Electric LC1K0601B7S335 — Contactors

Schneider LC1K0601B7S335 TeSys K Contactor, 6A AC-3, 24V AC

MPNLC1K0601B7S335
Obsolete

Schneider Electric TeSys K contactor, 3P, AC-3 ≤440V 6A, 1NC auxiliary, 24V AC coil, 45 x 58 x 57 mm.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

LC1K0601B7S335 — Identification
ParameterValue
Product / component typeContactor
Series / rangeTeSys
ApplicationMotor control
LC1K0601B7S335 — Ratings & Performance
ParameterValue
Utilisation categoryAC-3
LC1K0601B7S335 — Contacts & Poles
ParameterValue
Pole configuration3P
LC1K0601B7S335 — Environmental
ParameterValue
Operating altitude2000 m without derating
LC1K0601B7S335 — Mechanical
ParameterValue
Width45 mm
Height58 mm
Depth57 mm
LC1K0601B7S335 — Other specifications
ParameterValue
Range of productTeSys K
Device short nameLC1K
Pole contact composition3 NO
[Ie] rated operational current20 A (at 6 A at 16 A (at 10 MOhm for signalling circuit
Ambient air temperature for storage-50...80 °C

Product details

The LC1K0601B7S335 is a TeSys K three-pole contactor from Schneider Electric, rated for motor control in AC-3 utilisation category at 6 A up to 440 V. The 24 V AC coil and built-in 1NC auxiliary contact suit it for simple start/stop circuits in panel builds where a separate aux block isn't needed. The 45 x 58 x 57 mm footprint fits the standard TeSys K DIN-rail envelope, so it swaps into existing layouts without re-drilling the backplate.

Sourcing reality — obsolete, quoted to order

Schneider has marked the LC1K0601B7S335 as obsolete. If your panel design can accommodate a parametric substitute from the same TeSys K family, a sourcing specialist can help identify a current-production alternative that matches the 6 A AC-3, 24 V AC coil, and 1NC aux configuration.

The 6 A rated operational current in AC-3 (motor starting and disconnecting under load) means this contactor handles a standard 3 kW motor at 400 V three-phase — the typical duty cycle for small pumps, fans, and conveyors. The 24 V AC coil draws from a control transformer; verify the control circuit can supply the inrush without dropping below the pick-up voltage. Three normally-open power poles and one normally-closed auxiliary cover the basic three-wire start/stop scheme without extra components.

Frequently asked questions

What is the utilisation category and rated current?

It is rated 6 A in AC-3 (motor starting) up to 440 V, with three normally-open power poles.

MPN
LC1K0601B7S335