Schneider Electric LC1K0601L72 — Contactors

Schneider TeSys K LC1K0601L72 Contactor, 3P, 6 A, 200-208 VA

MPNLC1K0601L72
Obsolete

Schneider TeSys K contactor, 3P, AC-3 <= 440 V 6 A, 1 NC aux, 200-208 V AC coil, obsolete.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

LC1K0601L72 — Identification
ParameterValue
Product / component typeContactor
Series / rangeTeSys
LC1K0601L72 — Ratings & Performance
ParameterValue
Utilisation categoryAC-4 AC-3
LC1K0601L72 — Contacts & Poles
ParameterValue
Pole configuration3P
LC1K0601L72 — Environmental
ParameterValue
Flame retardanceV1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102
LC1K0601L72 — Mechanical
ParameterValue
Width45 mm
Height58 mm
Depth57 mm

Product details

The Schneider LC1K0601L72 is a TeSys K three-pole contactor rated for 6 A in AC-3 duty at up to 440 V, with a 200-208 V AC coil. It carries a single NC auxiliary contact and uses a built-in bidirectional peak limiting diode for coil suppression. Motor power capability ranges from 1.5 kW at 220-230 V up to 3 kW at 440-690 V, depending on line voltage.

The AC-3 rating of 6 A at 440 V governs motor switching — this contactor handles standard three-phase squirrel-cage motors up to that current. The AC-4 category also applies, meaning it can handle inching and plugging duty, though at reduced electrical life. The 1.3 W heat dissipation is modest, so panel thermal rise is minimal. Flame retardance meets UL 94 V1 and NF F 16-101/102, suitable for rail and industrial enclosures.

Frequently asked questions

What is the closest pin-compatible alternative to LC1K0601L72?

No official successor order code is recorded. A functional equivalent within the TeSys K or TeSys D family would need to match the 3-pole, 6 A AC-3 rating, 200-208 V AC coil, and 1 NC auxiliary contact. A parametric search against those specs is the practical route.

What are the motor power ratings for this contactor?

Motor power is 1.5 kW at 220-230 V AC, 2.2 kW at 380-415 V AC, and 3 kW at 440 V, 480 V, 500-600 V, and 660-690 V AC, all at 50/60 Hz.

What compliance documentation is available?

The contactor carries UL 94 V1 flame retardance rating and conforms to NF F 16-101 and NF F 16-102 for fire behavior. Standard Schneider documentation (declaration of conformity, RoHS/REACH) should be available through the manufacturer's support portal.

MPN