Skip to main content
Schneider Electric LC1K0601M7TQ — Contactors

Schneider LC1K0601M7TQ TeSys K Contactor, 3P, 6A AC-3, 220-2

MPNLC1K0601M7TQ
Obsolete

Schneider Electric TeSys K contactor, LC1K0601M7TQ, 3-pole, AC-3/AC-3e 6A at 440V, coil 220-230VAC 50/60Hz, screw clamp terminals.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

LC1K0601M7TQ — Identification
ParameterValue
Product / component typeContactor
Series / rangeTeSys
ApplicationMotor control
LC1K0601M7TQ — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: Signalling circuit: 10 MOhm for control circuit
Utilisation categoryAC-3 AC-3e AC-4
LC1K0601M7TQ — Contacts & Poles
ParameterValue
Pole configuration3P
LC1K0601M7TQ — Environmental
ParameterValue
Operating altitude2000 m without derating
Fire resistance850 °C conforming to IEC 60695-2-1
Flame retardanceClass C2 conforming to NF F 16-101 Class C2 conforming to NF F 16-102 V1 conforming to UL 94
LC1K0601M7TQ — Approvals
ParameterValue
StandardsEN/IEC 60947-4-1 GB/T 14048.4 UL 60947-4-1 CSA C22.2 No 60947-4-1 JIS C8201-4-1
LC1K0601M7TQ — Mechanical
ParameterValue
Width45 mm
Height58 mm
Depth57 mm

Product details

The Schneider Electric LC1K0601M7TQ is a TeSys K series contactor with three normally open power poles, rated for motor control in AC-3 and AC-3e utilisation categories at 6 A and 440 V. The coil is 220-230 VAC 50/60 Hz, drawing 30 VA inrush and 4.5 VA hold-in power at 20 °C. It mounts on a plate or DIN rail and uses screw clamp terminals accepting 0.34 to 4 mm² conductors.

AC-3e extends that to energy-efficient motors with higher inrush. The AC-4 rating at 36 A covers plugging and inching duty but at only 0.05 Mcycles electrical endurance, so it's not intended for frequent reversing.

The contactor is certified to EN/IEC 60947-4-1, GB/T 14048.4, UL 60947-4-1, CSA C22.2 No 60947-4-1, and JIS C8201-4-1. Flame retardance is V1 per UL 94 and Class C2 per NF F 16-101/102. Fire resistance is 850 °C per IEC 60695-2-1. Operating altitude is 2000 m without derating.

Integration notes

The screw clamp terminals accept one or two conductors per pole, solid or flexible with or without ferrules. Minimum switching capability is 5 mA at 17 V for the control circuit, so it can work with low-power PLC outputs. Coil dropout is at 20% of Uc, giving reliable release on voltage dips.

Frequently asked questions

What are the key ratings for this contactor?

It is a 3-pole contactor rated 6 A in AC-3/AC-3e at 440 V, with a coil of 220-230 VAC 50/60 Hz. AC-4 rating is 36 A at up to 440 V. Electrical endurance is 1.3 Mcycles for AC-3 loads and 0.05 Mcycles for AC-4.

What standards does the LC1K0601M7TQ comply with?

It complies with EN/IEC 60947-4-1, GB/T 14048.4, UL 60947-4-1, CSA C22.2 No 60947-4-1, and JIS C8201-4-1. Flame retardance is V1 per UL 94.

How do I source this obsolete part?

Since it is obsolete, sourcing is through the surplus and independent distributor channel. Submit an RFQ for current availability and pricing — no stock or lead time is held on this listing.

MPN
LC1K0601M7TQ