Schneider Electric LC1K0601Q72 — Contactors

TeSys K LC1K0601Q72 Contactor, 3P, 6 A, 380-400 VAC Coil

MPNLC1K0601Q72
Active

Schneider Electric TeSys K contactor, 3P, AC-3 <= 440 V 6 A, 1 NC auxiliary, 380...400 V AC coil, obsolete.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LC1K0601Q72 — Identification
ParameterValue
Product / component typeContactor
Series / rangeTeSys
LC1K0601Q72 — Ratings & Performance
ParameterValue
Utilisation categoryAC-3 AC-4
LC1K0601Q72 — Contacts & Poles
ParameterValue
Pole configuration3P
LC1K0601Q72 — Environmental
ParameterValue
Flame retardanceV1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102
LC1K0601Q72 — Mechanical
ParameterValue
Width45 mm
Height58 mm
Depth57 mm

Product details

The LC1K0601Q72 is a TeSys K three-pole contactor from Schneider Electric, rated for control applications in AC-3 and AC-4 utilisation categories. It switches motor loads up to 1.5 kW at 220–230 V AC, 2.2 kW at 380–415 V AC, and 3 kW at 440 V through 690 V AC, 50/60 Hz. The coil is 380–400 V AC with a built-in bidirectional peak-limiting diode suppressor. This is a compact unit — 45 mm wide, 58 mm high, 57 mm deep — sized for DIN-rail mounting in a control panel.

AC-4 rating means it can also handle plugging and inching duty, which is harder on the contacts. The 1 NC auxiliary contact (built into the order code suffix) gives you a feedback signal for the PLC or a holding circuit without adding a separate aux block. Flame retardance is V1 per UL 94, plus it meets NF F 16-101 and NF F 16-102 Requirement 2 — relevant if this goes into rail or transit applications where fire-smoke-toxicity standards apply.

Frequently asked questions

What is the closest alternative to LC1K0601Q72?

Within the TeSys K family, a current-production equivalent would need the same 3-pole, 6 A AC-3 rating, 1 NC auxiliary, and 380–400 V AC coil. The exact replacement depends on Schneider's current catalog — the form factor and DIN-rail footprint are consistent across the series, but the order code will differ. We can identify the specific cross-reference when you submit an RFQ with your application details.

What compliance documentation is available for this part?

The part carries UL 94 V1 flame retardance rating and meets NF F 16-101 and NF F 16-102 Requirement 2 for rail applications. Full RoHS, REACH, and UL documentation is available from the manufacturer's archive for obsolete parts; we can provide the compliance package with your order.

MPN