Schneider Electric LC1K0601Z7 — Contactors

Schneider TeSys K LC1K0601Z7 Contactor, 3P, 6 A, 20 V AC Coi

MPNLC1K0601Z7
Active

Schneider Electric TeSys K contactor, 3P, AC-3 ≤440 V 6 A, 1 NC aux, 20 V AC coil, active production.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LC1K0601Z7 — Identification
ParameterValue
Product / component typeContactor
Series / rangeTeSys
LC1K0601Z7 — Ratings & Performance
ParameterValue
Utilisation categoryAC-4 AC-3
LC1K0601Z7 — Contacts & Poles
ParameterValue
Pole configuration3P
LC1K0601Z7 — Environmental
ParameterValue
Flame retardanceV1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102
LC1K0601Z7 — Mechanical
ParameterValue
Width45 mm
Height58 mm
Depth57 mm
LC1K0601Z7 — Other specifications
ParameterValue
Motor power1.5 kW at 220...230 V AC 50/60 Hz 2.2 kW at 380...415 V AC 50/60 Hz 3 kW at 440 V AC 50/60 Hz 3 kW at 480 V AC 50/60 Hz 3 kW at 500...600 V AC 50/60 Hz 3 kW at 660...690 V AC 50/60 Hz
Heat dissipation1.3 W
Range of productTeSys K
Device short nameLC1K
Compatibility codeLC1K
Device applicationControl
Pole contact composition3 NO
[Ie] rated operational current6 A at 10 MOhm for signalling circuit
[Icw] rated short-time withstand current90 A 50 °C - 1 s for power circuit 85 A 50 °C - 5 s for power circuit 80 A 50 °C - 10 s for power circuit 60 A 50 °C - 30 s for power circuit 45 A 50 °C - 1 min for power circuit 40 A 50 °C - 3 min for power circuit 20 A 50 °C - >= 15 min for power circuit 80 A - 1 s for signalling circuit 90 A - 500 ms for signalling circuit 110 A - 100 ms for signalling circuit

Product details

What This Contactor Delivers

Rated for AC-3 duty at 6 A up to 440 V, it switches motor loads up to 1.5 kW on a 220–230 V supply, 2.2 kW at 380–415 V, and 3 kW across 440 V through 690 V lines — a single part that covers a wide range of common three-phase voltages without derating. The 20 V AC coil keeps the control circuit isolated from the power side, which simplifies panel wiring when the control transformer is sized for that voltage.

Frequently asked questions

What are the key motor power ratings for this contactor?

It handles 1.5 kW at 220–230 V AC, 2.2 kW at 380–415 V, and 3 kW at 440 V through 690 V AC, all at 50/60 Hz.

What utilisation categories does it carry?

It is rated for AC-3 (motor starting) and AC-4 (inching/plugging), so it is suited for both normal motor switching and reversing or jogging duty.