Skip to main content
Schneider Electric LC1K06105G7 — Contactors

Schneider LC1K06105G7 TeSys K Contactor, 3P, 6A, 120V AC Coi

MPNLC1K06105G7
Obsolete

Schneider Electric TeSys K contactor, 3P, AC-3 ≤440 V 6 A, 1 NO auxiliary contact, 120 V AC coil.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LC1K06105G7 — Identification
ParameterValue
Product / component typeContactor
Series / rangeTeSys
LC1K06105G7 — Ratings & Performance
ParameterValue
Utilisation categoryAC-3 AC-4
LC1K06105G7 — Contacts & Poles
ParameterValue
Pole configuration3P
LC1K06105G7 — Environmental
ParameterValue
Flame retardanceV1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102
LC1K06105G7 — Mechanical
ParameterValue
Width45 mm
Height58 mm
Depth57 mm
LC1K06105G7 — Other specifications
ParameterValue
Motor power1.5 kW at 220...230 V AC 50/60 Hz 2.2 kW at 380...415 V AC 50/60 Hz 3 kW at 440 V AC 50/60 Hz 3 kW at 480 V AC 50/60 Hz 3 kW at 500...600 V AC 50/60 Hz 3 kW at 660...690 V AC 50/60 Hz
Heat dissipation1.3 W
Range of productTeSys K
Device short nameLC1K
Compatibility codeLC1K
Device applicationControl
Pole contact composition3 NO
[Ie] rated operational current6 A at 10 MOhm for signalling circuit
[Icw] rated short-time withstand current90 A 50 °C - 1 s for power circuit 85 A 50 °C - 5 s for power circuit 80 A 50 °C - 10 s for power circuit 60 A 50 °C - 30 s for power circuit 45 A 50 °C - 1 min for power circuit 40 A 50 °C - 3 min for power circuit 20 A 50 °C - >= 15 min for power circuit 80 A - 1 s for signalling circuit 90 A - 500 ms for signalling circuit 110 A - 100 ms for signalling circuit

Product details

The Schneider LC1K06105G7 is a TeSys K three-pole contactor rated for AC-3 and AC-4 duty, meaning it switches motor loads — not just resistive heaters. The AC-3 rating of 6 A at ≤440 V covers small three-phase motors up to 1.5 kW at 230 V or 2.2 kW at 400 V, and up to 3 kW on 480 V and higher supplies. The 120 V AC coil pulls in reliably on the control voltage you'd expect from a standard panel transformer.

The 6 A rating is the operational current in AC-3 category — the one that governs motor switching. The short-time withstand current (Icw) of 90 A for 1 second means it can ride through a locked-rotor inrush without welding contacts. Heat dissipation is only 1.3 W, so you can pack it tight on a DIN rail without cooking adjacent devices.

Frequently asked questions

What are the key ratings of the LC1K06105G7?

AC-3 rated operational current 6 A at ≤440 V. Motor power up to 3 kW depending on supply voltage. Coil 120 V AC. Three main poles, one NO auxiliary contact.

What is the physical size of the LC1K06105G7?

45 mm wide, 58 mm high, 57 mm deep — standard 45 mm DIN-rail footprint.

MPN
LC1K06105G7