Skip to main content
Schneider Electric LC1K06105T7 — Contactors

Schneider LC1K06105T7 TeSys K Contactor, 6A AC-3, 480V Coil

MPNLC1K06105T7
Obsolete

Schneider Electric TeSys K contactor, 3P, AC-3 <= 440 V 6 A, 1 NO aux., 480 V AC coil, obsolete.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LC1K06105T7 — Identification
ParameterValue
Product / component typeContactor
Series / rangeTeSys
LC1K06105T7 — Ratings & Performance
ParameterValue
Utilisation categoryAC-3 AC-4
LC1K06105T7 — Contacts & Poles
ParameterValue
Pole configuration3P
LC1K06105T7 — Environmental
ParameterValue
Flame retardanceV1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102
LC1K06105T7 — Mechanical
ParameterValue
Width45 mm
Height58 mm
Depth57 mm
LC1K06105T7 — Other specifications
ParameterValue
Motor power1.5 kW at 220...230 V AC 50/60 Hz 2.2 kW at 380...415 V AC 50/60 Hz 3 kW at 440 V AC 50/60 Hz 3 kW at 480 V AC 50/60 Hz 3 kW at 500...600 V AC 50/60 Hz 3 kW at 660...690 V AC 50/60 Hz
Heat dissipation1.3 W
Range of productTeSys K
Device short nameLC1K
Compatibility codeLC1K
Device applicationControl
Pole contact composition3 NO
[Ie] rated operational current6 A at 10 MOhm for signalling circuit
[Icw] rated short-time withstand current90 A 50 °C - 1 s for power circuit 85 A 50 °C - 5 s for power circuit 80 A 50 °C - 10 s for power circuit 60 A 50 °C - 30 s for power circuit 45 A 50 °C - 1 min for power circuit 40 A 50 °C - 3 min for power circuit 20 A 50 °C - >= 15 min for power circuit 80 A - 1 s for signalling circuit 90 A - 500 ms for signalling circuit 110 A - 100 ms for signalling circuit

Product details

The coil is 480 V AC, so it pulls in on a 480 V control circuit. A single NO auxiliary contact is built in for feedback or interlocking. Motor power capability varies with line voltage: 1.5 kW at 220–230 V, 2.2 kW at 380–415 V, and 3 kW at 440 V through 690 V. Heat dissipation is 1.3 W — negligible in a crowded panel, but worth noting if you are packing relays next to temperature-sensitive electronics.

Frequently asked questions

What are the key ratings for this contactor?

Three-pole, normally open. Rated operational current is 6 A in AC-3 utilisation category (motor switching) up to 440 V. Coil is 480 V AC. Motor power ranges from 1.5 kW at 220–230 V up to 3 kW at 440–690 V. One NO auxiliary contact is included.

What compliance documentation does Schneider provide for this part?

The part carries UL 94 V1 flame retardance rating and meets NF F 16-101 and NF F 16-102 Requirement 2 for fire behaviour. Standard Schneider declarations for RoHS and REACH would apply to the original production batch; for surplus stock, compliance documentation depends on the specific lot and should be requested at time of quote.

MPN
LC1K06105T7