Skip to main content
Schneider Electric LC1K06106Q7 — Contactors

Schneider TeSys K LC1K06106Q7 Contactor, 3P AC-3 6A, 380-400

MPNLC1K06106Q7
Obsolete

Schneider Electric TeSys K contactor, LC1K06106Q7, 3-pole, AC-3 6 A at ≤440 V, 380...400 V AC coil, 1 NO auxiliary contact, obsolete.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

LC1K06106Q7 — Identification
ParameterValue
Product / component typeContactor
Series / rangeTeSys
LC1K06106Q7 — Ratings & Performance
ParameterValue
Utilisation categoryAC-4 AC-3
LC1K06106Q7 — Contacts & Poles
ParameterValue
Pole configuration3P
LC1K06106Q7 — Environmental
ParameterValue
Flame retardanceV1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102
LC1K06106Q7 — Mechanical
ParameterValue
Width45 mm
Height58 mm
Depth57 mm

Product details

It carries a 380...400 V AC coil and one normally open auxiliary contact. The three-pole design with NO main contacts handles resistive and inductive loads across the AC-3 and AC-4 utilisation categories. Motor power capability spans 1.5 kW at 220...230 V AC up to 3 kW at 440...690 V AC, making it suitable for small pumps, fans, and conveyors across common three-phase supply voltages.

The TeSys K series has been superseded by the TeSys Deca range. Verify cross-reference for coil voltage and auxiliary configuration.

The compact footprint — 45 mm wide, 58 mm high, 57 mm deep — fits standard DIN-rail enclosures and leaves room for adjacent devices in crowded panels. Heat dissipation is a modest 1.3 W, so no special ventilation is needed in normal industrial environments. Flame retardance meets UL 94 V1 and NF F 16-101/102 requirements, which is relevant for rail and transport applications where fire safety is specified.

The AC-4 category covers inching and plugging duty, where the contactor sees higher electrical stress. Short-time withstand current (Icw) is 90 A for 1 second on the power circuit, giving coordination headroom for upstream protective devices. The signalling circuit can handle 110 A for 100 ms.

Frequently asked questions

What replaces the LC1K06106Q7?

The TeSys K series has been superseded by the TeSys Deca range. A direct replacement must be verified for coil voltage (380-400 V AC), pole configuration (3P), and auxiliary contact count (1 NO). Contact us with your application details for a cross-reference.

What are the key specifications of this contactor?

It is a 3-pole contactor rated 6 A in AC-3 at ≤440 V, with a 380-400 V AC coil and one NO auxiliary contact. Motor power ranges from 1.5 kW at 230 V to 3 kW at 480-690 V. Dimensions are 45 x 58 x 57 mm.

What compliance documentation is available?

The contactor carries UL 94 V1 flame retardance and NF F 16-101/102 compliance for rail applications. Standard Schneider documentation (datasheet, CE declaration) is available on request.

MPN