The LC1K06106R7 is a 3-pole TeSys K contactor rated 6 A in AC-3 duty at ≤440 V, meaning it switches three-phase motor loads up to that current — the AC-3 category covers starting and stopping squirrel-cage motors under load. Motor power equivalents are 1.5 kW at 220–230 V, 2.2 kW at 380–415 V, and 3 kW at 440–690 V, so the same contactor covers a 400 V class motor in Europe and a 480 V motor in North America without a frame size change. The 440 V AC coil draws its control voltage from the line side or a separate control transformer; verify the coil matches your control circuit voltage before panel wiring. The contactor carries AC-4 ratings as well, which covers plugging and inching duty where the motor is reversed or jogged under load — a harder switching condition that derates the current. For pure AC-4 use, expect to downrate from the 6 A AC-3 figure. The 1 NO auxiliary contact is built in; additional aux blocks can be added on the side for feedback or interlocking.
Schneider LC1K06106R7 TeSys K Contactor, 3P 6A AC-3, 440V AC
Schneider Electric TeSys K contactor, LC1K06106R7, 3-pole, AC-3 6 A at ≤440 V, 1 NO auxiliary contact, 440 V AC 50/60 Hz coil.
Specifications
| Parameter | Value |
|---|---|
| Product / component type | Contactor |
| Series / range | TeSys |
| Parameter | Value |
|---|---|
| Utilisation category | AC-4 AC-3 |
| Parameter | Value |
|---|---|
| Pole configuration | 3P |
| Parameter | Value |
|---|---|
| Flame retardance | V1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102 |
| Parameter | Value |
|---|---|
| Width | 45 mm |
| Height | 58 mm |
| Depth | 57 mm |
Product details
Frequently asked questions
What motor sizes does the LC1K06106R7 cover?
It covers 1.5 kW at 220–230 V AC, 2.2 kW at 380–415 V AC, and 3 kW at 440–690 V AC, all at 50/60 Hz. This means one contactor handles a 2.2 kW European 400 V motor or a 3 kW North American 480 V motor.
What compliance documentation is available for this contactor?
The contactor carries UL 94 V1 flame retardance and NF F 16-101/102 Requirement 2 for railway fire safety. RoHS and REACH declarations are available from the manufacturer.
What is the closest alternative in the TeSys K family?
The LC1K0610 is the same frame with a 6 A AC-3 rating but a different coil voltage. If your control circuit is 440 V AC, this LC1K06106R7 is the correct coil variant. For a 24 V DC coil or 230 V AC coil, the order code suffix changes — the base contactor body and aux contact count are identical.