Skip to main content
Schneider Electric LC1K06106R7 — Contactors

Schneider LC1K06106R7 TeSys K Contactor, 3P 6A AC-3, 440V AC

MPNLC1K06106R7
Active

Schneider Electric TeSys K contactor, LC1K06106R7, 3-pole, AC-3 6 A at ≤440 V, 1 NO auxiliary contact, 440 V AC 50/60 Hz coil.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LC1K06106R7 — Identification
ParameterValue
Product / component typeContactor
Series / rangeTeSys
LC1K06106R7 — Ratings & Performance
ParameterValue
Utilisation categoryAC-4 AC-3
LC1K06106R7 — Contacts & Poles
ParameterValue
Pole configuration3P
LC1K06106R7 — Environmental
ParameterValue
Flame retardanceV1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102
LC1K06106R7 — Mechanical
ParameterValue
Width45 mm
Height58 mm
Depth57 mm
LC1K06106R7 — Other specifications
ParameterValue
Motor power1.5 kW at 220...230 V AC 50/60 Hz 2.2 kW at 380...415 V AC 50/60 Hz 3 kW at 440 V AC 50/60 Hz 3 kW at 480 V AC 50/60 Hz 3 kW at 500...600 V AC 50/60 Hz 3 kW at 660...690 V AC 50/60 Hz
Heat dissipation1.3 W
Range of productTeSys K
Device short nameLC1K
Compatibility codeLC1K
Device applicationControl
Pole contact composition3 NO
[Ie] rated operational current6 A at 10 MOhm for signalling circuit
[Icw] rated short-time withstand current90 A 50 °C - 1 s for power circuit 85 A 50 °C - 5 s for power circuit 80 A 50 °C - 10 s for power circuit 60 A 50 °C - 30 s for power circuit 45 A 50 °C - 1 min for power circuit 40 A 50 °C - 3 min for power circuit 20 A 50 °C - >= 15 min for power circuit 80 A - 1 s for signalling circuit 90 A - 500 ms for signalling circuit 110 A - 100 ms for signalling circuit

Product details

The LC1K06106R7 is a 3-pole TeSys K contactor rated 6 A in AC-3 duty at ≤440 V, meaning it switches three-phase motor loads up to that current — the AC-3 category covers starting and stopping squirrel-cage motors under load. Motor power equivalents are 1.5 kW at 220–230 V, 2.2 kW at 380–415 V, and 3 kW at 440–690 V, so the same contactor covers a 400 V class motor in Europe and a 480 V motor in North America without a frame size change. The 440 V AC coil draws its control voltage from the line side or a separate control transformer; verify the coil matches your control circuit voltage before panel wiring. The contactor carries AC-4 ratings as well, which covers plugging and inching duty where the motor is reversed or jogged under load — a harder switching condition that derates the current. For pure AC-4 use, expect to downrate from the 6 A AC-3 figure. The 1 NO auxiliary contact is built in; additional aux blocks can be added on the side for feedback or interlocking.

Frequently asked questions

What motor sizes does the LC1K06106R7 cover?

It covers 1.5 kW at 220–230 V AC, 2.2 kW at 380–415 V AC, and 3 kW at 440–690 V AC, all at 50/60 Hz. This means one contactor handles a 2.2 kW European 400 V motor or a 3 kW North American 480 V motor.

What compliance documentation is available for this contactor?

The contactor carries UL 94 V1 flame retardance and NF F 16-101/102 Requirement 2 for railway fire safety. RoHS and REACH declarations are available from the manufacturer.

What is the closest alternative in the TeSys K family?

The LC1K0610 is the same frame with a 6 A AC-3 rating but a different coil voltage. If your control circuit is 440 V AC, this LC1K06106R7 is the correct coil variant. For a 24 V DC coil or 230 V AC coil, the order code suffix changes — the base contactor body and aux contact count are identical.

MPN