Skip to main content
Schneider Electric LC1K06107FE7 — Contactors

Schneider TeSys K LC1K06107FE7 Contactor, 3P, 6A AC-3, 115V

MPNLC1K06107FE7
Active

Schneider Electric TeSys K contactor, LC1K06107FE7, 3-pole, AC-3 rated 6 A at ≤440 V, 1 NO auxiliary contact, 115 V AC 50/60 Hz coil.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LC1K06107FE7 — Identification
ParameterValue
Product / component typeContactor
Series / rangeTeSys
LC1K06107FE7 — Ratings & Performance
ParameterValue
Utilisation categoryAC-4 AC-3
LC1K06107FE7 — Contacts & Poles
ParameterValue
Pole configuration3P
LC1K06107FE7 — Environmental
ParameterValue
Flame retardanceV1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102
LC1K06107FE7 — Mechanical
ParameterValue
Width45 mm
Height58 mm
Depth57 mm
LC1K06107FE7 — Other specifications
ParameterValue
Motor power1.5 kW at 220...230 V AC 50/60 Hz 2.2 kW at 380...415 V AC 50/60 Hz 3 kW at 440 V AC 50/60 Hz 3 kW at 480 V AC 50/60 Hz 3 kW at 500...600 V AC 50/60 Hz 3 kW at 660...690 V AC 50/60 Hz
Heat dissipation1.3 W
Range of productTeSys K
Device short nameLC1K
Compatibility codeLC1K
Device applicationControl
Pole contact composition3 NO
[Ie] rated operational current6 A at 10 MOhm for signalling circuit
[Icw] rated short-time withstand current90 A 50 °C - 1 s for power circuit 85 A 50 °C - 5 s for power circuit 80 A 50 °C - 10 s for power circuit 60 A 50 °C - 30 s for power circuit 45 A 50 °C - 1 min for power circuit 40 A 50 °C - 3 min for power circuit 20 A 50 °C - >= 15 min for power circuit 80 A - 1 s for signalling circuit 90 A - 500 ms for signalling circuit 110 A - 100 ms for signalling circuit

Product details

The Schneider Electric TeSys K LC1K06107FE7 is a 3-pole contactor with a 115 V AC coil, rated 6 A in AC-3 utilisation category at ≤440 V. The 6 A AC-3 figure is the real-world switching limit for motor duty; the part also carries an AC-4 rating for inching and plugging applications where the motor is reversed or stopped by counter-torque.

Motor power coverage

This contactor covers motor loads up to 1.5 kW at 220–230 V AC, 2.2 kW at 380–415 V AC, and 3 kW at 440 V, 480 V, 500–600 V, and 660–690 V AC — all at 50/60 Hz. The single unit spans the common European and North American voltage bands, which simplifies BOM consolidation when a panel ships to multiple regions. The 3 kW ceiling at 480 V matches a standard 3 HP motor frame in North American practice.

Physical integration

The 3 NO main poles and 1 NO auxiliary contact are wired via screw terminals. The 115 V AC coil draws from a control transformer or direct line supply; verify the coil voltage matches your control circuit before panel wiring.

Frequently asked questions

What motor power does this contactor handle at 480 V?

It is rated for 3 kW at 480 V AC, 50/60 Hz in AC-3 duty, which corresponds to a standard 3 HP motor frame.

What is the closest alternative within the TeSys K family?

Within the same TeSys K frame, the LC1K0610 series shares the same 6 A AC-3 rating and 3-pole configuration. The difference is the coil voltage — the FE7 suffix specifies 115 V AC 50/60 Hz. A different coil voltage variant (e.g., 24 V AC, 230 V AC) would be the same contactor with a different coil, mechanically and electrically interchangeable in the panel.

What compliance documentation is available for this part?

The contactor carries UL 94 V-1 flame retardance certification on its enclosure material and meets NF F 16-101/102 class 2 for rail applications. As a Schneider TeSys product, it is typically CE-marked and UL-listed; specific RoHS/REACH declarations are available through the manufacturer's documentation portal.

MPN
LC1K06107FE7