Skip to main content
Schneider Electric LC1K0610K72 — Contactors

TeSys K LC1K0610K72 Contactor, 3P, 6A AC-3, 100V AC Coil

MPNLC1K0610K72
Active

Schneider Electric TeSys K LC1K0610K72, 3-pole contactor, AC-3/AC-3e 6 A at 440 V, 1 NO auxiliary contact, 100 V AC coil with integral suppression device.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LC1K0610K72 — Identification
ParameterValue
Product / component typeContactor
Series / rangeTeSys
ApplicationMotor control
LC1K0610K72 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: Signalling circuit: 10 MOhm for signalling circuit
Utilisation categoryAC-3 AC-3e AC-4
LC1K0610K72 — Contacts & Poles
ParameterValue
Pole configuration3P
LC1K0610K72 — Environmental
ParameterValue
IP degree of protectionIP2X conforming to VDE 0106
Operating altitude2000 m without derating
Mechanical robustnessShocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6
Protective treatment / pollution degreeTC conforming to IEC 60068 TC conforming to DIN 50016
Flame retardanceV1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102
LC1K0610K72 — Approvals
ParameterValue
StandardsEN/IEC 60947-4-1 GB/T 14048.4 UL 60947-4-1 CSA C22.2 No 60947-4-1 JIS C8201-4-1 IEC 60335-1:Clause 30.2 IEC 60335-2-40:Annex JJ UL 60335-2-40:Annex JJ
LC1K0610K72 — Mechanical
ParameterValue
Width45 mm
Height58 mm
Depth57 mm

Product details

Where it fits and how it connects

The 45 mm width and 58 mm height fit the compact TeSys K footprint — three of these side by side take about 135 mm of DIN rail, leaving room for a terminal block or a small PLC in a standard 400 mm enclosure. Screw clamp terminals accept 1.5 to 4 mm² solid or 0.75 to 4 mm² flexible, with a tightening torque of 0.8 to 1.3 N·m using a No. 2 Phillips or Pozidriv. IP2X finger protection per VDE 0106 means it's safe for open-panel use where operators might reach near the terminals, though it's not sealed against dust or moisture — keep it inside a cabinet rated to the environment.

Frequently asked questions

What are the key ratings for this contactor?

Rated 6 A in AC-3/AC-3e at 440 V for motor control, with an AC-4 rating of 36 A. The coil is 100 V AC with integral suppression. Electrical durability is 1.3 million cycles under AC-3, mechanical durability 10 million cycles.

What compliance documentation is available for the LC1K0610K72?

It carries certifications to EN/IEC 60947-4-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, JIS C8201-4-1, and GB/T 14048.4. It also meets IEC 60335-1 and IEC 60335-2-40 appliance standards, plus NF F 16-101/102 for rail. Flame retardance is UL 94 V1.

MPN