Schneider Electric LC1K09004M7TQ — Contactors

Schneider TeSys K LC1K09004M7TQ contactor, 4-pole AC-1 20A

MPNLC1K09004M7TQ
Active

Schneider Electric TeSys K contactor, LC1K09004M7TQ, 4-pole, AC-1 440V 20A, 220..230 V AC coil, 45 x 58 x 57 mm.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LC1K09004M7TQ — Identification
ParameterValue
Product / component typeContactor
Series / rangeTeSys
LC1K09004M7TQ — Ratings & Performance
ParameterValue
Utilisation categoryAC-1
LC1K09004M7TQ — Contacts & Poles
ParameterValue
Pole configuration4P
LC1K09004M7TQ — Environmental
ParameterValue
Flame retardanceClass C2 conforming to NF F 16-101 Class C2 conforming to NF F 16-102 V1 conforming to UL 94
LC1K09004M7TQ — Mechanical
ParameterValue
Width45 mm
Height58 mm
Depth57 mm
LC1K09004M7TQ — Other specifications
ParameterValue
Coil technologyWithout built-in bidirectional peak limiting diode suppressor
Range of productTeSys K
Device short nameLC1K
Compatibility codeLC1K
Control circuit typeAC
Pole contact composition4 NO
[Ie] rated operational current20 A (at 10 MOhm for control circuit

Product details

The Schneider Electric TeSys K LC1K09004M7TQ is a 4-pole contactor with 4 normally-open power poles, a 220-230 V AC coil, and a rated operational current of 20 A in utilisation category AC-1 at 440 V. AC-1 is the utilisation category for resistive or slightly inductive loads — heaters, lighting banks, or furnace elements — where the switching current and the breaking current are essentially the same because there's no significant motor inrush or back-EMF. The coil is AC-operated, no built-in bidirectional peak-limiting diode suppressor, so if you're adding a suppression module externally (recommended for PLC-driven coils or long control-wire runs), match it to the 220-230 V AC coil voltage and expect a standard RC snubber or MOV.

Frequently asked questions

What is the closest alternative to this contactor within the TeSys K family?

The closest pin-compatible sibling is the LC1K09004M7T (same 4-pole, 20 A AC-1, but with a 220 V AC coil instead of 220-230 V). The LC1K09004M7TQ has a wider coil tolerance band (220-230 V), which can help if your control transformer output sags under load. Both share the same 45 mm footprint, same pole configuration, and same auxiliary add-ons.

What is the depth of this contactor?

The depth is 57 mm measured from the DIN-rail mounting foot to the front face of the contactor body.

What compliance documentation is available for this part?

The part carries flame retardance certifications: Class C2 per NF F 16-101 and NF F 16-102 (railway fire behaviour), and V1 per UL 94. Additional compliance (RoHS, REACH, UL listing, IEC 60947) is standard for the TeSys K range but not individually confirmed in this listing.

MPN
LC1K09004M7TQ