Skip to main content
Schneider Electric LC1K09013K7 — Contactors

TeSys K LC1K09013K7 Contactor, 3P AC-3 9A, 100VAC Coil

MPNLC1K09013K7
Active

Schneider Electric TeSys K contactor, LC1K09013K7, 3P, AC-3 ≤ 440 V 9 A, 1 NC auxiliary, 100 V AC coil, 57 mm depth.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LC1K09013K7 — Identification
ParameterValue
Product / component typeContactor
Series / rangeTeSys
LC1K09013K7 — Ratings & Performance
ParameterValue
Utilisation categoryAC-4 AC-1 AC-3
LC1K09013K7 — Contacts & Poles
ParameterValue
Pole configuration3P
LC1K09013K7 — Environmental
ParameterValue
Flame retardanceV1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102
LC1K09013K7 — Mechanical
ParameterValue
Width45 mm
Height58 mm
Depth57 mm
LC1K09013K7 — Other specifications
ParameterValue
Motor power4 kW at 480 V AC 50/60 Hz 4 kW at 500...600 V AC 50/60 Hz 4 kW at 660...690 V AC 50/60 Hz 2.2 kW at 220...230 V AC 50/60 Hz 4 kW at 380...415 V AC 50/60 Hz 4 kW at 440 V AC 50/60 Hz
Heat dissipation1.3 W
Range of productTeSys K
Device short nameLC1K
Compatibility codeLC1K
Device applicationControl
Pole contact composition3 NO
[Ie] rated operational current20 A (at 9 A at 16 A (at 10 MOhm for signalling circuit
[Icw] rated short-time withstand current90 A 50 °C - 1 s for power circuit 85 A 50 °C - 5 s for power circuit 80 A 50 °C - 10 s for power circuit 60 A 50 °C - 30 s for power circuit 45 A 50 °C - 1 min for power circuit 40 A 50 °C - 3 min for power circuit 20 A 50 °C - >= 15 min for power circuit 80 A - 1 s for signalling circuit 90 A - 500 ms for signalling circuit 110 A - 100 ms for signalling circuit

Product details

Product Identification and Key Ratings

The LC1K09013K7 is a TeSys K three-pole contactor from Schneider Electric, rated for AC-3 duty at 9 A up to 440 V with a 100 V AC coil. It carries one normally closed auxiliary contact. The part is now classified as obsolete per the manufacturer's lifecycle status. For motor switching, the contactor is rated at 4 kW on 380–415 V AC, 480 V, 500–600 V, and 660–690 V supplies at 50/60 Hz, and 2.2 kW at 220–230 V AC. The rated operational current is 20 A, with AC-3 switching current at 9 A and AC-1 at 16 A. The contactor measures 57 mm deep, 45 mm wide, and 58 mm high, fitting standard DIN-rail enclosures. Heat dissipation is 1.3 W. The enclosure material meets flame retardance class V1 per UL 94, and also complies with NF F 16-101 and NF F 16-102 requirements.

Sourcing and Lifecycle Position

The LC1K09013K7 is obsolete. No successor order code is listed. Source this part through independent channels against an RFQ.

Utilisation Categories and Application Context

The contactor is rated for utilisation categories AC-1 (resistive loads), AC-3 (squirrel-cage motors: starting, switching off during running), and AC-4 (plugging, inching, reversing). The AC-3 rating of 9 A at ≤440 V defines its primary motor-switching capability. For audit purposes, the rated short-time withstand current (Icw) is 90 A for 1 second on the power circuit, and 110 A for 100 ms on the signalling circuit.

Frequently asked questions

What are the key ratings for the LC1K09013K7?

It is a 3-pole contactor rated AC-3 at 9 A up to 440 V with a 100 V AC coil. Motor power ratings include 4 kW at 380–415 V, 480 V, 500–600 V, and 660–690 V AC, and 2.2 kW at 220–230 V AC. The contactor has one NC auxiliary contact and measures 57 mm deep by 45 mm wide by 58 mm high.

What compliance documentation is available for this contactor?

The contactor carries flame retardance rating V1 per UL 94, and also complies with NF F 16-101 and NF F 16-102 requirements. The evidence does not list RoHS, REACH, or additional UL certification details for this specific order code.

How can I source the LC1K09013K7 now that it is obsolete?

As an obsolete part, it is sourced through independent surplus and broker channels. Submit an RFQ for current availability and pricing; no manufacturer lead time applies.

MPN