Schneider Electric LC1K09015V7TQ — Contactors

Schneider TeSys K LC1K09015V7TQ Contactor, 9 A, 400 VAC Coil

MPNLC1K09015V7TQ
Obsolete

Schneider Electric TeSys K contactor, 3P, AC-3 9 A at ≤440 V, 1 NC aux, 400 V AC coil, TQ packaging.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LC1K09015V7TQ — Identification
ParameterValue
Product / component typeContactor
Series / rangeTeSys
LC1K09015V7TQ — Ratings & Performance
ParameterValue
Utilisation categoryAC-3 AC-1 AC-4
LC1K09015V7TQ — Contacts & Poles
ParameterValue
Pole configuration3P
LC1K09015V7TQ — Environmental
ParameterValue
Flame retardanceV1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102
LC1K09015V7TQ — Mechanical
ParameterValue
Width45 mm
Height58 mm
Depth57 mm
LC1K09015V7TQ — Other specifications
ParameterValue
Motor power4 kW at 480 V AC 50/60 Hz 4 kW at 500...600 V AC 50/60 Hz 4 kW at 660...690 V AC 50/60 Hz 2.2 kW at 220...230 V AC 50/60 Hz 4 kW at 380...415 V AC 50/60 Hz 4 kW at 440 V AC 50/60 Hz
Heat dissipation1.3 W
Range of productTeSys K
Device short nameLC1K
Compatibility codeLC1K
Device applicationControl
Pole contact composition3 NO
[Ie] rated operational current20 A (at 9 A at 16 A (at 10 MOhm for signalling circuit
[Icw] rated short-time withstand current90 A 50 °C - 1 s for power circuit 85 A 50 °C - 5 s for power circuit 80 A 50 °C - 10 s for power circuit 60 A 50 °C - 30 s for power circuit 45 A 50 °C - 1 min for power circuit 40 A 50 °C - 3 min for power circuit 20 A 50 °C - >= 15 min for power circuit 80 A - 1 s for signalling circuit 90 A - 500 ms for signalling circuit 110 A - 100 ms for signalling circuit

Product details

The Schneider Electric LC1K09015V7TQ is a TeSys K three-pole contactor rated for 9 A in AC-3 duty at up to 440 V, with a 400 V AC coil and one NC auxiliary contact. It's built for switching motor loads — the AC-3 category covers starting and stopping squirrel-cage motors, and the 4 kW rating at 480 V (and up to 690 V) lines up with typical small-pump, fan, or conveyor applications in a control panel.

The AC-1 rating (resistive load) is higher, but for motor duty, stick with AC-3. The 400 V AC coil means it's designed for a 400 V control supply, common in European and IEC panels.

The TeSys K series shares the same mounting pattern as other TeSys K contactors, so swapping in a like-for-like replacement is straightforward if the panel layout is already drilled or rail-mounted.

The contactor carries a V1 flame-retardance rating per UL 94 and meets NF F 16-101 and NF F 16-102 requirements. That's relevant for rail and industrial applications where fire safety is specified. No other approvals (UL, CSA, CE) are listed in the record, so verify against your local code requirements if that's a gate for your panel.

Frequently asked questions

What are the motor power ratings for this contactor?

It's rated for 4 kW at 480 V AC, 4 kW at 500–600 V AC, 4 kW at 660–690 V AC, 2.2 kW at 220–230 V AC, and 4 kW at 380–415 V AC — all at 50/60 Hz. These cover common three-phase motor sizes in IEC panels.

What is the depth of the LC1K09015V7TQ?

57 mm.

What is the utilisation category for this contactor?

It's rated for AC-1 (resistive), AC-3 (squirrel-cage motor starting/stopping), and AC-4 (plugging/inching). The AC-3 rating of 9 A at ≤440 V is the key one for motor switching.

MPN