Schneider Electric LC1K09016SLS207 — Contactors

Schneider LC1K09016SLS207 TeSys K Contactor, 9A AC-3, 72V DC

MPNLC1K09016SLS207
Obsolete

Schneider Electric TeSys K series, LC1K09016SLS207, 3-pole contactor, 9 A AC-3 at ≤440 V, 72 V DC low-consumption coil with integral suppression, 1 NC auxiliary contact.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

LC1K09016SLS207 — Identification
ParameterValue
Product / component typeContactor
Series / rangeTeSys
ApplicationMotor control Resistive load
LC1K09016SLS207 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: Signalling circuit: 10 MOhm for signalling circuit
Utilisation categoryAC-3 AC-3e AC-1 AC-4
LC1K09016SLS207 — Contacts & Poles
ParameterValue
Pole configuration3P
LC1K09016SLS207 — Environmental
ParameterValue
IP degree of protectionIP20 conforming to VDE 0106
Operating altitude2000 m without derating
Mechanical robustnessShocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6
Protective treatment / pollution degreeTC conforming to IEC 60068 TC conforming to DIN 50016
Flame retardanceV0 conforming to UL 94
LC1K09016SLS207 — Approvals
ParameterValue
StandardsBS 5424 IEC 60947 NF C 63-110 VDE 0660 IEC 60077-1 IEC 60077-2 EN 45545: R22 HL3 EN/IEC 60947-4-1 EN/IEC 60947-5-1 UL 60947-4-1 CSA C22.2 No 60947-4-1
LC1K09016SLS207 — Mechanical
ParameterValue
Width45 mm
Height58 mm
Depth57 mm

Product details

The Schneider Electric LC1K09016SLS207 is a TeSys K series 3-pole contactor rated for 9 A in AC-3 utilisation category at ≤440 V, making it a direct fit for switching small to medium motor loads in control panels. The 72 V DC low-consumption coil draws only 1.8 W at 20 °C and includes an integral suppression device, so no external flyback diode or RC snubber is needed on the coil circuit — just wire the DC supply directly. The main poles are 3 NO, and a single 1 NC auxiliary contact is built in for feedback or interlocking.

The 9 A AC-3 rating at ≤440 V is the motor-switching current — this contactor will handle a 3-phase motor drawing up to 9 A under full load, with the ability to break the motor's locked-rotor current during starting. The AC-1 rating (resistive load) is higher, but for motor duty the AC-3 figure governs selection. The 72 V DC coil operates reliably from 0.7 to 1.3 times nominal voltage (roughly 50.4 to 93.6 V DC) and drops out at ≥0.1 Uc below 50 °C. Coil energisation closes the NO contacts in 30 to 40 ms; de-energisation opens them in 10 to 20 ms. The 1.8 W hold-in power means minimal heat in a crowded panel. Mechanical durability is rated at 30 million cycles, and electrical durability at 1.3 million cycles at 9 A AC-3. The B10d value of 1,369,863 cycles under nominal load (per EN/ISO 13849-1) supports use in safety-related control circuits up to certain performance levels. The IP20 finger-safe protection (per VDE 0106) means it is suitable for installation inside an enclosed panel where no water or dust ingress is expected.

Mounts on either a DIN rail or a flat plate. Power connections accept ring terminals with a 7 mm outer diameter. The 1 NC auxiliary contact is instantaneous — no delay.

Frequently asked questions

What are the key ratings for this contactor?

It is a 3-pole contactor rated 9 A in AC-3 at ≤440 V, with a 72 V DC low-consumption coil drawing 1.8 W hold-in power. It includes one 1 NC auxiliary contact and has a mechanical durability of 30 million cycles.

What compliance documentation does this part carry?

It is approved to IEC 60947-4-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, EN 45545 (R22 HL3), and other standards. The housing is V-0 rated per UL 94.

What is the closest alternative in the TeSys K family?

Within the TeSys K range, the LC1K0901 series shares the same 9 A AC-3 rating and 3-pole configuration but differs in coil voltage. The LC1K09016SLS207 specifically uses a 72 V DC low-consumption coil with integral suppression — verify coil voltage compatibility before substituting.