Skip to main content
Schneider Electric LC1K0901K7 — Contactors

Schneider TeSys K LC1K0901K7 Contactor, 3P 9A AC-3, 100V AC

MPNLC1K0901K7
Obsolete

Schneider Electric TeSys K series, LC1K0901K7, 3-pole contactor, 9 A AC-3/AC-3e at ≤440 V, 100 V AC coil, 1 NC auxiliary contact, screw clamp terminals.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LC1K0901K7 — Identification
ParameterValue
Product / component typeContactor
Series / rangeTeSys
ApplicationMotor control Resistive load
LC1K0901K7 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: Signalling circuit: 10 MOhm for signalling circuit
Utilisation categoryAC-3 AC-3e AC-1 AC-4
LC1K0901K7 — Contacts & Poles
ParameterValue
Pole configuration3P
LC1K0901K7 — Environmental
ParameterValue
Operating altitude2000 m without derating
Mechanical robustnessShocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6
Protective treatment / pollution degreeTC conforming to IEC 60068 TC conforming to DIN 50016
Flame retardanceV1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102
LC1K0901K7 — Approvals
ParameterValue
StandardsEN/IEC 60947-4-1 GB/T 14048.4 UL 60947-4-1 CSA C22.2 No 60947-4-1 JIS C8201-4-1 IEC 60335-1:Clause 30.2 IEC 60335-2-40:Annex JJ UL 60335-2-40:Annex JJ
LC1K0901K7 — Mechanical
ParameterValue
Width45 mm
Height58 mm
Depth57 mm

Product details

The LC1K0901K7: This is a 3-pole contactor from the TeSys K range, rated 9 A in AC-3 and AC-3e utilisation categories at ≤440 V — the standard duty for squirrel-cage motor switching. The 9 A AC-3 rating governs the motor full-load current it can handle; for a 400 V three-phase induction motor, this corresponds to approximately 4 kW. The 100 V AC coil (50/60 Hz) pulls 30 VA inrush and holds at 4.5 VA, dissipating 1.3 W. The single normally-closed (1 NC) auxiliary contact is built in, with a minimum switching capability of 5 mA at 17 V for signalling circuits — adequate for PLC input status feedback. Electrical durability varies by load: 1.3 million cycles at 9 A AC-3, 160,000 cycles at 20 A AC-1 (resistive), and only 20,000 cycles at 54 A AC-4 (plugging/inching). For safety circuit integration, the B10d value is 1,369,863 cycles under nominal load per EN/ISO 13849-1, rising to 20 million cycles under purely mechanical (no-load) operation.

Compliance & Certification

The contactor carries full compliance with EN/IEC 60947-4-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, JIS C8201-4-1, and GB/T 14048.4. It also meets IEC 60335-1 Clause 30.2 and IEC 60335-2-40 Annex JJ for appliance applications. Flame retardance is V1 per UL 94, and the part is certified to NF F 16-101/102 for railway fire behaviour. The protective treatment is TC (tropical climate) per IEC 60068 and DIN 50016.

Mechanical Integration

Screw-clamp terminals accept 1.5 to 4 mm² solid or 0.34 to 2.5 mm² flexible with ferrule, with a strip length suitable for standard terminal blocks. Operating altitude is 2000 m without derating; shock resistance is 10-15 Gn depending on axis and contactor state.

Frequently asked questions

What are the key ratings of the LC1K0901K7?

3-pole contactor, 9 A AC-3/AC-3e at ≤440 V, 100 V AC coil, 1 NC auxiliary contact. Electrical durability is 1.3 Mcycles at 9 A AC-3. Compliant with EN/IEC 60947-4-1, UL, CSA, JIS, and GB standards.

What compliance documentation is available for this contactor?

The part is certified to EN/IEC 60947-4-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, JIS C8201-4-1, and GB/T 14048.4. It also meets IEC 60335-1/2-40 appliance standards and NF F 16-101/102 railway fire behaviour requirements.

MPN
LC1K0901K7