Skip to main content
Schneider Electric LC1K09103K7 — Contactors

TeSys K LC1K09103K7 Contactor, 3P, 9 A AC-3, 100 V AC Coil

MPNLC1K09103K7
Active

Schneider Electric TeSys K contactor, LC1K09103K7, 3-pole, AC-3 rated 9 A at ≤440 V, 100 V AC coil, 1 NO auxiliary contact.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LC1K09103K7 — Identification
ParameterValue
Product / component typeContactor
Series / rangeTeSys
LC1K09103K7 — Ratings & Performance
ParameterValue
Utilisation categoryAC-3 AC-1 AC-4
LC1K09103K7 — Contacts & Poles
ParameterValue
Pole configuration3P
LC1K09103K7 — Environmental
ParameterValue
Flame retardanceV1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102
LC1K09103K7 — Mechanical
ParameterValue
Width45 mm
Height58 mm
Depth57 mm
LC1K09103K7 — Other specifications
ParameterValue
Motor power4 kW at 480 V AC 50/60 Hz 4 kW at 500...600 V AC 50/60 Hz 4 kW at 660...690 V AC 50/60 Hz 2.2 kW at 220...230 V AC 50/60 Hz 4 kW at 380...415 V AC 50/60 Hz 4 kW at 440 V AC 50/60 Hz
Heat dissipation1.3 W
Range of productTeSys K
Device short nameLC1K
Compatibility codeLC1K
Device applicationControl
Pole contact composition3 NO
[Ie] rated operational current20 A (at 9 A at 16 A (at 10 MOhm for signalling circuit
[Icw] rated short-time withstand current90 A 50 °C - 1 s for power circuit 85 A 50 °C - 5 s for power circuit 80 A 50 °C - 10 s for power circuit 60 A 50 °C - 30 s for power circuit 45 A 50 °C - 1 min for power circuit 40 A 50 °C - 3 min for power circuit 20 A 50 °C - >= 15 min for power circuit 80 A - 1 s for signalling circuit 90 A - 500 ms for signalling circuit 110 A - 100 ms for signalling circuit

Product details

The LC1K09103K7 is a 3-pole TeSys K contactor rated 9 A in AC-3 duty at ≤440 V, which is the standard motor-switching category — so it handles a 4 kW motor at 480 V or a 2.2 kW motor at 220...230 V. The 100 V AC coil draws about 1.3 W heat dissipation, a figure to budget for in a crowded DIN-rail enclosure. One normally-open auxiliary contact is built in; if you need more, the TeSys K range accepts add-on auxiliary blocks.

At 45 mm wide, 58 mm tall, and 57 mm deep, this contactor fits the standard DIN-rail footprint for compact motor starters. The V1 flame-retardant housing (UL 94 V1) is standard for control panels. For a 4 kW motor at 480 V, the AC-3 rating is the one that governs — AC-1 (resistive) and AC-4 (inching/plugging) are also listed but at lower currents.

Frequently asked questions

What are the key motor power ratings for this contactor?

It is rated for 4 kW at 480 V AC, 4 kW at 500...600 V AC, 4 kW at 660...690 V AC, 4 kW at 380...415 V AC, 4 kW at 440 V AC, and 2.2 kW at 220...230 V AC, all at 50/60 Hz.

What is the depth of LC1K09103K7?

The depth is 57 mm.

What compliance documentation is available?

The housing is rated V1 per UL 94 and also meets NF F 16-101 and NF F 16-102 flame-retardance requirements. Standard Schneider declarations for RoHS, REACH, and UL/CSA/CE apply to the TeSys K series.

MPN
LC1K09103K7