Schneider Electric LC1K09103P72 — Contactors

Schneider TeSys K LC1K09103P72 Contactor, 3P, 9A AC-3, 230VA

MPNLC1K09103P72
Active

Schneider Electric TeSys K contactor, 3P, AC-3 ≤440V 9A, 1 NO aux., 230V AC coil with built-in bidirectional peak limiting diode suppressor.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LC1K09103P72 — Identification
ParameterValue
Product / component typeContactor
Series / rangeTeSys
LC1K09103P72 — Ratings & Performance
ParameterValue
Utilisation categoryAC-4 AC-3 AC-1
LC1K09103P72 — Contacts & Poles
ParameterValue
Pole configuration3P
LC1K09103P72 — Environmental
ParameterValue
Flame retardanceV1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102
LC1K09103P72 — Mechanical
ParameterValue
Width45 mm
Height58 mm
Depth57 mm
LC1K09103P72 — Other specifications
ParameterValue
Motor power4 kW at 480 V AC 50/60 Hz 4 kW at 500...600 V AC 50/60 Hz 4 kW at 660...690 V AC 50/60 Hz 2.2 kW at 220...230 V AC 50/60 Hz 4 kW at 380...415 V AC 50/60 Hz 4 kW at 440 V AC 50/60 Hz
Coil technologyBuilt-in bidirectional peak limiting diode suppressor
Heat dissipation1.3 W
Range of productTeSys K
Compatibility codeLC1K
Device applicationControl
Pole contact composition3 NO
[Ie] rated operational current20 A (at 9 A at 16 A (at 10 MOhm for signalling circuit

Product details

It carries a 9 A rated operational current in AC-3 utilisation category at voltages up to 440 V, and can switch motor loads up to 4 kW at 480 V AC 50/60 Hz. The 230 V AC coil includes a built-in bidirectional peak limiting diode suppressor, so you don't need to add an external snubber for inductive load switching.

The AC-1 rating of 20 A covers resistive loads like heaters. AC-4 is also listed for plugging and inching duty, though that's harder on the contacts. Heat dissipation is 1.3 W — modest enough that you won't need to derate adjacent components in a dense DIN-rail layout, but worth including in your panel thermal budget if you're stacking several contactors.

The 3 NO main poles and 1 NO auxiliary contact are wired via screw terminals. The built-in coil suppression means the control circuit sees less back-EMF, which extends the life of your PLC output or relay driving it.

Frequently asked questions

What motor power can this contactor handle?

It handles 4 kW at 480 V AC, 4 kW at 500...600 V AC, 4 kW at 660...690 V AC, 2.2 kW at 220...230 V AC, 4 kW at 380...415 V AC, and 4 kW at 440 V AC — all at 50/60 Hz.

Does the coil need an external suppression diode?

No. The coil has a built-in bidirectional peak limiting diode suppressor, so no external snubber or flyback diode is required across the coil terminals.

What compliance certifications does this contactor carry?

It is rated V1 conforming to UL 94 for flame retardance, and meets Requirement 2 of both NF F 16-101 and NF F 16-102 for railway fire behaviour.

MPN
LC1K09103P72