Skip to main content
Schneider Electric LC1K0986BLS207 — Contactors

Schneider TeSys LC1K0986BLS207 Contactor, 24 V DC, 20 A AC-1

MPNLC1K0986BLS207
Active

Schneider Electric TeSys LC1K contactor, LC1K0986BLS207, 4-pole, 24 V DC coil with integral suppression, 20 A AC-1 rated operational current, IP20.

$92.45Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

LC1K0986BLS207 — Identification
ParameterValue
Product / component typeContactor
Series / rangeTeSys
ApplicationResistive load
LC1K0986BLS207 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: Signalling circuit: <= 690 V AC <= 400 Hz
Utilisation categoryAC-1
LC1K0986BLS207 — Contacts & Poles
ParameterValue
Pole configuration4P
LC1K0986BLS207 — Environmental
ParameterValue
IP degree of protectionIP20 conforming to VDE 0106
Operating altitude2000 m without derating
Mechanical robustnessShocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6
Protective treatment / pollution degreeTC conforming to IEC 60068 TC conforming to DIN 50016
Flame retardanceV0 conforming to UL 94
LC1K0986BLS207 — Approvals
ParameterValue
StandardsBS 5424 IEC 60947 NF C 63-110 VDE 0660 IEC 60077-1 IEC 60077-2 EN 45545: R22 HL3 EN/IEC 60947-4-1 EN/IEC 60947-5-1 UL 60947-4-1 CSA C22.2 No 60947-4-1
LC1K0986BLS207 — Mechanical
ParameterValue
Width45 mm
Height58 mm
Depth57 mm

Product details

It's rated for 20 A in AC-1 utilisation category (resistive loads) at up to 690 V, so it's sized for switching heater banks, lighting, or other non-inductive loads in a control panel. The contact arrangement is 2 NO + 2 NC, giving you flexibility for both power and auxiliary signalling on the same device.

The coil holds in at 0.7 to 1.3 times Uc (16.8 to 31.2 V DC) and drops out below 0.1 Uc (2.4 V DC), so it's tolerant of a sagging 24 V supply but will drop cleanly on a brownout. The 1.8 W hold-in power at 20 °C means it won't cook neighbouring components in a tightly packed enclosure. The power circuit connections use ring terminals with an external diameter of 7 mm, torqued to 0.8–1.3 N·m.

Frequently asked questions

What is the closest alternative to LC1K0986BLS207 in the TeSys family?

Within the TeSys LC1K range, a direct peer would be a 4-pole contactor with the same coil voltage and pole configuration. The key difference to check is the rated operational current — the LC1K0986BLS207 is specified at 20 A AC-1. If your load requires a different current, look for a sibling with a matching Ie rating and the same 24 V DC coil.

What compliance documentation does Schneider provide for this contactor?

The contactor is certified to IEC 60947-4-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, EN 45545 (R22 HL3), and meets V-0 flame retardance per UL 94. Schneider typically provides a Declaration of Conformity covering these standards.

MPN
LC1K0986BLS207