Skip to main content
Schneider Electric LC1K12004R7 — Contactors

TeSys K LC1K12004R7 Contactor, 4P 20 A AC-1, 440 V AC Coil

MPNLC1K12004R7
Active

Schneider Electric TeSys K contactor, 4P (4 NO), AC-1 ≤440 V 20 A, 440 V AC 50/60 Hz coil, obsolete.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LC1K12004R7 — Identification
ParameterValue
Product / component typeContactor
Series / rangeTeSys
ApplicationResistive load
LC1K12004R7 — Ratings & Performance
ParameterValue
Utilisation categoryAC-1
LC1K12004R7 — Contacts & Poles
ParameterValue
Pole configuration4P
LC1K12004R7 — Environmental
ParameterValue
Operating altitude2000 m without derating
Mechanical robustnessShocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6
Protective treatment / pollution degreeTC conforming to IEC 60068 TC conforming to DIN 50016
Flame retardanceV1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102
LC1K12004R7 — Approvals
ParameterValue
StandardsEN/IEC 60947-4-1 GB/T 14048.4 UL 60947-4-1 CSA C22.2 No 60947-4-1 JIS C8201-4-1
LC1K12004R7 — Mechanical
ParameterValue
Width45 mm
Height58 mm
Depth57 mm

Product details

The LC1K12004R7 is a TeSys K 4-pole contactor with four normally open (4 NO) power poles, a 440 V AC 50/60 Hz coil, and an AC-1 utilisation category rating of 20 A at ≤440 V for resistive loads. It is certified to EN/IEC 60947-4-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, and JIS C8201-4-1, making it accepted in North American, European, and Japanese regulatory jurisdictions. The conventional free-air thermal current (Ith) is 20 A at 50 °C for the power circuit, and the rated breaking capacity reaches 110 A at 440 V, 80 A at 500 V, and 70 A at 660–690 V per IEC 60947.

The AC-1 rating of 20 A at ≤440 V governs resistive loads such as heaters or lighting — not motor starting (AC-3). For motor duty, the contactor is not rated in AC-3, so a different TeSys K variant with an AC-3 rating would be needed. The 440 V AC coil operates at 50/60 Hz with a hold-in power consumption of 4.5 VA and inrush of 30 VA at 20 °C; control voltage limits are 0.8–1.15 Uc for pick-up and 0.2–0.75 Uc for drop-out below 50 °C. The 4 NO pole configuration means all four poles switch the line side — no auxiliary contacts are built in. The associated fuse rating is 25 A gG or 25 A aM for the power circuit. Mechanical robustness is documented: the closed contactor withstands shocks of 10 Gn on X axis and 15 Gn on Y/Z axes per IEC 60068-2-27, and vibrations of 4 Gn at 5–300 Hz when closed.

Frequently asked questions

What compliance documentation does this contactor carry?

It is certified to EN/IEC 60947-4-1, GB/T 14048.4, UL 60947-4-1, CSA C22.2 No 60947-4-1, and JIS C8201-4-1. The enclosure material is rated V1 per UL 94 and meets NF F 16-101/102 Requirement 2 for flame retardance. Protective treatment conforms to IEC 60068 and DIN 50016.

What are the physical dimensions of this contactor?

Depth is 57 mm, width 45 mm, height 58 mm. These dimensions are for the contactor body itself and are relevant for panel layout and DIN-rail spacing.

What is the closest alternative to this obsolete part?

No official successor order code is listed. A replacement would need to match the 4 NO pole configuration, 440 V AC 50/60 Hz coil, and AC-1 current rating of 20 A at ≤440 V. A parametric search within the TeSys K family or the newer TeSys Deca series would be the starting point, but pin compatibility and mounting footprint must be verified against the specific panel layout.

MPN