Skip to main content
Schneider Electric LC1K12016K7 — Contactors

Schneider LC1K12016K7 TeSys K Contactor, 3P, 12A AC-3, 100V

MPNLC1K12016K7
Obsolete

Schneider Electric TeSys K contactor, 3P, AC-3/AC-3e 12A at 440V, 100V AC coil, 1NC auxiliary contact, obsolete.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LC1K12016K7 — Identification
ParameterValue
Product / component typeContactor
Series / rangeTeSys
ApplicationMotor control Resistive load
LC1K12016K7 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: Signalling circuit: 10 MOhm for signalling circuit
Utilisation categoryAC-3 AC-3e AC-1 AC-4
LC1K12016K7 — Contacts & Poles
ParameterValue
Pole configuration3P
LC1K12016K7 — Environmental
ParameterValue
Operating altitude2000 m without derating
Mechanical robustnessShocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6
Protective treatment / pollution degreeTC conforming to IEC 60068 TC conforming to DIN 50016
Flame retardanceV1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102
LC1K12016K7 — Approvals
ParameterValue
StandardsEN/IEC 60947-4-1 GB/T 14048.4 UL 60947-4-1 CSA C22.2 No 60947-4-1 JIS C8201-4-1 IEC 60335-1:Clause 30.2 IEC 60335-2-40:Annex JJ UL 60335-2-40:Annex JJ
LC1K12016K7 — Mechanical
ParameterValue
Width45 mm
Height58 mm
Depth57 mm

Product details

The Schneider Electric LC1K12016K7 is a TeSys K three-pole contactor rated for 12 A in AC-3 duty at 440 V, with a 100 V AC coil and one normally-closed auxiliary contact. It also carries AC-1 (resistive) and AC-4 (plugging/inching) ratings, giving it flexibility for non-motor loads or high-stress reversing duty. The 1NC auxiliary is built in, no add-on block needed for basic interlock or status feedback.

The headline rating is 12 A in AC-3 at 440 V — this is the motor-switching current the contactor is designed to handle. Electrical durability at that rating is 1.3 million cycles, which is typical for a compact TeSys K frame. Mechanical durability is 10 million cycles, so the mechanism outlasts the electrical life under normal use. The coil draws 30 VA inrush and 4.5 VA hold-in at 20 °C; the 100 V AC coil must stay within 0.8 to 1.15 times nominal voltage to pull in reliably, and drops out at 20% of nominal.

The 3-pole power circuit uses ring-terminal lugs with a 7 mm outer diameter. The 1NC auxiliary contact is wired separately. Heat dissipation is 1.3 W, so no special ventilation is needed in a standard enclosure.

Frequently asked questions

What is the closest replacement for the LC1K12016K7?

No official successor order code is published in the lifecycle record. A parametric match would need the same 3-pole, 12 A AC-3, 100 V AC coil, 1NC auxiliary contact in a TeSys K or TeSys D frame. Because the coil voltage and auxiliary count are specific, verify fit before committing a BOM line.

What are the key ratings for the LC1K12016K7?

12 A in AC-3 at 440 V, 100 V AC coil, 1NC auxiliary contact. Electrical durability is 1.3 million cycles at the AC-3 rating. Mechanical durability is 10 million cycles.

What compliance documentation is available for the LC1K12016K7?

The contactor is certified to EN/IEC 60947-4-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, and JIS C8201-4-1. It also meets IEC 60335-1 Clause 30.2 and IEC 60335-2-40 Annex JJ. Flame retardance is V1 per UL 94.

MPN
LC1K12016K7